## Abstract A reversed‐phase high performance liquid chromatography method has been developed and validated for determination and quantitation of the natural sesquiterpene (−)‐__α__‐bisabolol. Furthermore the application of the method was done by characterization of chitosan milispheres and liposom
Development and validation of a high-performance liquid chromatography method for the simultaneous determination of aspirin and folic acid from nano-particulate systems
✍ Scribed by Abhishek Chaudhary; Jeffrey Wang; Sunil Prabhu
- Publisher
- John Wiley and Sons
- Year
- 2009
- Tongue
- English
- Weight
- 364 KB
- Volume
- 24
- Category
- Article
- ISSN
- 0269-3879
- DOI
- 10.1002/bmc.1386
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Attention has shifted from the treatment of colorectal cancer (CRC) to chemoprevention using aspirin and folic acid as agents capable of preventing the onset of colon cancer. However, no sensitive analytical method exists to simultaneously quantify the two drugs when released from polymer‐based nanoparticles. Thus, a rapid, highly sensitive method of high‐performance liquid chromatography analysis to simultaneously detect low quantities of aspirin (hydrolyzed to salicylic acid, the active moiety) and folic acid released from biodegradable polylactide‐co‐glycolide (PLGA) copolymer nanoparticles was developed. Analysis was done on a reversed‐phase C~18~ column using a photodiode array detector at wavelengths of 233 nm (salicylic acid) and 277 nm (folic acid). The mobile phase consisted of acetonitrile–0.1% trifluoroacetic acid mixture programmed for a 30 min gradient elution analysis. In the range of 0.1–100 μg/mL, the assay showed good linearity for salicylic acid (R^2^ = 0.9996) and folic acid (R^2^ = 0.9998). The method demonstrated good reproducibility, intra‐ and inter‐day precision and accuracy (99.67, 100.1%) and low values of detection (0.03, 0.01 μg/mL) and quantitation (0.1 and 0.05 μg/mL) for salicylic acid and folic acid, respectively. The suitability of the method was demonstrated by simultaneously determining salicylic acid and folic acid released from PLGA nanoparticles. Copyright © 2009 John Wiley & Sons, Ltd.
📜 SIMILAR VOLUMES
Street cocaine varies in purity and is often adulterated with various compounds. Some of these additives, such as lidocaine, may increase the toxicity of cocaine. A new precise, accurate and sensitive reversedphase high-performance liquid chromatography method for the determination of cocaine, its m
The objective was to develop a simple HPLC method to quantify exenatide-a 39 amino acid residue incretin mimetic used in diabetes therapy. To date, only non-validated, sometimes incomplete, gradient methods have been reported in the literature. Isocratic separation was achieved using a C4 column and
A simple high-performance liquid chromatographic method for the determination of doxazosin in human plasma was developed and validated. Prazosin was used as internal standard. After extraction twice with ethyl acetate, chromatographic separation of doxazosin in human plasma was carried out using a r
A high performance liquid chromatography (HPLC) method has been developed for the simultaneous determination of plasma levels of theophylline and its metabolites without interference from caffeine or caffeine metabolites. The method is simple and of practical use because it is applicable even to pla