𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Determination of triclosan in human dental plaque by gas chromatography with atomic emission detection

✍ Scribed by Rasmussen, Henrik T. ;McDonough, Robert ;Gargiullo, Robert J. ;McPherson, Bruce P.


Publisher
John Wiley and Sons
Year
1996
Tongue
English
Weight
320 KB
Volume
19
Category
Article
ISSN
0935-6304

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

A validated gas chromatographic method for the determination of triclosan in human dental plaque is described. Based on plaque sample weights of 10 mg, the limit of detection (2 Γ— S/N) is 0.5 ΞΌg/g. The method is linear (r = 0.9986) from the limit of detection to 50 ΞΌg/g. Recoveries from placebos spiked with 2.0, 25, and 50 ΞΌg/g of triclosan were 105.6%Β±7.5%, 107.2%Β±3.1%, and 99.1%Β±1.1%, respectively (n = 3 at each level). Twenty replicate preparations and analyses of a homogenized sample, conducted by two operators over the course of 4 days, showed agreement to within 9% RSD. Analyses of dental plaque collected from patients after brushing with dental cream containing triclosan, shows triclosan to be retained in dental plaque at concentrations above the minimum inhibitory concentration (1 ΞΌg/g) after 12 h.


πŸ“œ SIMILAR VOLUMES


Determination of ethers and alcohols in
✍ Diehl, J. W. ;Finkbeiner, J. W. ;di Sanzo, Frank P. πŸ“‚ Article πŸ“… 1995 πŸ› John Wiley and Sons 🌐 English βš– 255 KB

## Abstract A GC method for the determination of oxygenated additives in reformulated gasolines (RFG) is described. The method uses on‐column injection and atomic emission selective detection of oxygenates using the 777 nm NIR emission line. Detection limits are approximately 10 ppm oxygen. Results

Determination of the volatiles from toba
✍ Gang Li; Da Wu; Ye Wang; Wenyan Xie; Xiangmin Zhang; Baizhan Liu πŸ“‚ Article πŸ“… 2011 πŸ› John Wiley and Sons 🌐 English βš– 195 KB

## Abstract A new gas chromatograph‐atomic emission detector (GC‐AED) coupled with Deans switching technique for analyzing volatiles from tobaccos were developed. The detector operating parameters (reagent gas pressure and make‐up gas flow rate) were optimized. The detection limits for the elements

Determination of methylcyclopentadienylm
✍ Y. K. Chau; F. Yang; M. Brown πŸ“‚ Article πŸ“… 1997 πŸ› John Wiley and Sons 🌐 English βš– 85 KB πŸ‘ 2 views

A highly sensitive and specific method is described for the determination of methylcyclopentadienylmanganese tricarbonyl (MMT) in gasoline and environmental samples by gas chromatography-plasma atomic emission detection (GC-AED). The procedure is simple, rapid and free from interferences. The absolu

Factors affecting C:H and C:N ratios det
✍ Pedersen-Bjergaard, Stig ;Asp, Tone Normann ;Greibrokk, Tyge πŸ“‚ Article πŸ“… 1992 πŸ› John Wiley and Sons 🌐 English βš– 399 KB

## Abstract An atomic emission detector has been evaluated for the estimation of C:H and C:N ratios of compounds eluted in gas chromatography. When C:H and C:N ratios were estimated using external reference compounds, the greatest accuracy was obtained when the quantity of the reference compound wa

Determination of lidocaine in human seru
✍ Arimoto, Hiromi ;Shiomi, Koichi ;Fujii, Toshihiro πŸ“‚ Article πŸ“… 1991 πŸ› John Wiley and Sons 🌐 English βš– 311 KB πŸ‘ 1 views

## Abstract A novel analytical method has been developed for the determination of lidocaine (2‐(diethylamino)‐__N__‐(2,6‐dimethyl)phenylacetamide) in human serum. After solvent extraction from serum the extract was analyzed by gas chromatography employing a __van den Berg__ type solventless injecto