An novel analytical method consisting of flow-injection sampling and chemiluminescence (CL) detection for determination of anticancer drug hydroxycamptothecinum (HCPT) is described. It is based on the CL reaction of potassium permanganate-formaldehyde-HCPT system. The formaldehyde-sensitized CL emis
Determination of propafenone hydrochloride by flow-injection analysis coupled with resonance light scattering detection
✍ Scribed by Xiaoli Hu; Dongpo Xu; Shaopu Liu; Zhongfang Liu; Sa Liu
- Publisher
- John Wiley and Sons
- Year
- 2009
- Tongue
- English
- Weight
- 186 KB
- Volume
- 24
- Category
- Article
- ISSN
- 1522-7235
- DOI
- 10.1002/bio.1068
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
A simple, sensitive and rapid flow injection analysis (FIA) method with resonance light scattering (RLS) was described for the determination of propafenone (PPF). The method was based on the ion‐association reaction of 12‐tungstophosphoric acid (TP) with propafenone. In pH 1.0 acidic medium, TP reacted with PPF to form an ion‐associate complex, which resulted in a significant enhancement of RLS intensity. The maximum scattering peak was located at 340 nm, the RLS intensity was proportional to the concentration of PPF in the range 0.003–9.0 µg/mL, and the detection limit (3__σ__) of 1.0 ng/mL was obtained at a sampling rate of 60 samples/h. The feasible reaction conditions and FIA parameters for the system were optimized. The method proposed in this paper shows satisfactory reproducibility with a relative standard deviation (RSD) of 2.1% for 10 successive determinations of 2.0 µg/mL PPF. The present method had been successfully applied to the determination of PPF in serum samples and pharmaceutical samples. The results obtained were in agreement with the method used in the Chinese Pharmacopoeia. Copyright © 2008 John Wiley & Sons, Ltd.
📜 SIMILAR VOLUMES
## Abstract A new Ag(III) complex‐luminol chemiluminescent system which was applied to the determination of epinephrine is firstly reported. Based on the enhancing effect of epinephrine on the chemiluminescence reaction of luminol with [Ag(HIO~6~)~2~]^5−^ in alkaline solution, a highly sensitive ch
Flow injection analysis (F1A)/chemiluminescence detection has been used to the determination of Al(III), Zn(II), Cd(II), and In(III). Fluorescent compound which was formed by complexation of a metal ion and 8-hydroxyquinoline was excited by the chemiluminescence reaction of bis(2,4,6trichlorophenyl)
A flow injection analysis method for determining L-carnitine is reported. The system uses the enzyme L-carnitine dehydrogenase covalently immobilized to Eupergit C. The NADH produced by the action of the enzyme, which is proportional to the L-carnitine concentration, is quantified using fluorescence