𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Determination of organotin compounds in environmental samples by supercritical fluid extraction and gas chromatography with atomic emission detection

✍ Scribed by Liu, Yan ;Lopez-Avila, Viorica ;Alcaraz, Marcela ;Beckert, Werner F.


Publisher
John Wiley and Sons
Year
1993
Tongue
English
Weight
709 KB
Volume
16
Category
Article
ISSN
0935-6304

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

The extraction of six tetraalkyltin and seven ionic organotin compounds from spiked topsoil samples with supercritical carbon dioxide and carbon dioxide modified with 5 percent methanol was investigated. Analysis of the soil extracts was performed by gas chromatography with atomic emission detection. Retention times, minimum detectable concentrations, and detector linear ranges are included for nine organotin compounds (seven of the nine compounds were derivatized with n‐pentylmagnesium bromide prior to gas chromatographic analysis). A 2^3^ factorial experimental design was used to study the effect of three variables (pressure, temperature, and extraction time) on compound recovery. The results indicate that the tetraalkyltin compounds are extracted from topsoil samples with recoveries ranging from 90 to 110 percent. Recoveries for the ionic organotin compounds ranged from 50 to 75 percent for trimethyltin chloride, triethyltin bromide, and tributyltin iodide; they were below 20 percent for dimethyltin dichloride, dibutyltin dichloride, diphenyltin dichloride, and butyltin trichloride. When sodium diethyldithiocarbamate was added to the soil samples prior to extraction, followed by extraction with carbon dioxide modified with 5 percent methanol, recoveries ranged from 70 to 90 percent for trimethyltin chloride, triethyltin bromide, dimethyltin dichloride, tributyltin iodide, and dibutyltin dichloride; recoveries were approximately 40 percent for butyltin trichloride and diphenyltin dichloride.


πŸ“œ SIMILAR VOLUMES


Simultaneous determination of organotin,
✍ Liu, Yan ;Lopez-Avila, Viorica ;Alcaraz, Marcela ;Beckert, Werner F. πŸ“‚ Article πŸ“… 1994 πŸ› John Wiley and Sons 🌐 English

## Abstract As part of a continuing evaluation of new analytical and sample preparation techniques conducted by the US Environmental Protection Agency (EPA), the use of capillary gas chromatography with atomic emission detection (GC‐AED) for the simultaneous determination of organotin, organolead,

Molecular formula determination of halog
✍ Stig Pedersen-Bjergaard; Tone Normann Asp; John Vedde; Tyge Greibrokk πŸ“‚ Article πŸ“… 1992 πŸ› John Wiley and Sons 🌐 English βš– 568 KB

## Abstract Atomic emission spectroscopy coupled with capillary gas chromatography (GC) has been evaluated for molecular formula determination of several chlorinated and brominated compounds present in three environmental samples. Variations in elemental responses due to compound type, poor chromat

Determination of methylcyclopentadienylm
✍ Y. K. Chau; F. Yang; M. Brown πŸ“‚ Article πŸ“… 1997 πŸ› John Wiley and Sons 🌐 English βš– 85 KB πŸ‘ 2 views

A highly sensitive and specific method is described for the determination of methylcyclopentadienylmanganese tricarbonyl (MMT) in gasoline and environmental samples by gas chromatography-plasma atomic emission detection (GC-AED). The procedure is simple, rapid and free from interferences. The absolu

Determination of triclosan in human dent
✍ Rasmussen, Henrik T. ;McDonough, Robert ;Gargiullo, Robert J. ;McPherson, Bruce πŸ“‚ Article πŸ“… 1996 πŸ› John Wiley and Sons 🌐 English βš– 320 KB

## Abstract A validated gas chromatographic method for the determination of triclosan in human dental plaque is described. Based on plaque sample weights of 10 mg, the limit of detection (2 Γ— __S/N__) is 0.5 ΞΌg/g. The method is linear (__r__ = 0.9986) from the limit of detection to 50 ΞΌg/g. Recover

Determination of ethers and alcohols in
✍ Diehl, J. W. ;Finkbeiner, J. W. ;di Sanzo, Frank P. πŸ“‚ Article πŸ“… 1995 πŸ› John Wiley and Sons 🌐 English βš– 255 KB

## Abstract A GC method for the determination of oxygenated additives in reformulated gasolines (RFG) is described. The method uses on‐column injection and atomic emission selective detection of oxygenates using the 777 nm NIR emission line. Detection limits are approximately 10 ppm oxygen. Results