𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Determination of eight sulfonamides in bovine kidney by liquid chromatography/tandem mass spectrometry with on-line extraction and sample clean-up

✍ Scribed by Nico Van Eeckhout; José Castro Perez; Carlos Van Peteghem


Publisher
John Wiley and Sons
Year
2000
Tongue
English
Weight
125 KB
Volume
14
Category
Article
ISSN
0951-4198

No coin nor oath required. For personal study only.

✦ Synopsis


A sensitive, high performance liquid chromatography/tandem mass spectrometric (i.e. mass spectrometry/ mass spectrometry; LC/MS/MS) method with on-line extraction and sample clean-up for the screening and confirmation of residues of sulfonamides in kidney is described. The sulfonamides are extracted from homogenized kidney with methanol. After centrifugation of the extract, an aliquot of the extract is directly injected on the LC/MS/MS system with further extraction and clean-up of the sample on-line. Detection of the analytes was achieved by positive electrospray ionization (ESI) followed by multiple reaction monitoring. For each sulfonamide the collisional decomposition of the protonated molecule to a common, abundant fragment ion was monitored. The method has been validated for sulfadimethoxine, sulfaquinoxaline, sulfamethazine, sulfamerazine, sulfathiazole, sulfamethoxazole, sulfadiazine and sulfapyridine.

Calibration curves resulting from spiked blank kidney samples at the 10-200 mg/kg level showed good linear correlation. At the level of 50, 100 and 200 mg/kg both within-and between-day precision, as measured by relative standard deviation (RSD), were less than 16%. The limits of detection (LODs) ranged from 5 to 13.5 mg/kg. The recoveries ranged from 78 to 82%. The procedure provides a rapid, reliable and sensitive method for the determination of residues of sulfonamides in bovine kidney. The advantage of this method over existing methods is its decreased sample preparation and analysis time, which makes the method more suitable for routine analysis.


📜 SIMILAR VOLUMES


Determination of tetracyclines in bovine
✍ Nico Van Eeckhout; José Castro Perez; Jan Claereboudt; Renaat Vandeputte; Carlos 📂 Article 📅 2000 🏛 John Wiley and Sons 🌐 English ⚖ 90 KB 👁 1 views

A novel, sensitive, high performance liquid chromatography/tandem mass spectrometric (i.e. mass spectrometry/mass spectrometry) method with on-line extraction and clean-up for the screening and confirmation of residues of tetracyclines in kidney has been developed. After liquid extraction of homogen

Determination of methotrexate in environ
✍ Roberta Turci; Giuseppina Micoli; Claudio Minoia 📂 Article 📅 2000 🏛 John Wiley and Sons 🌐 English ⚖ 126 KB 👁 1 views

In order to assess exposure levels of hospital personnel involved in the preparation and administration of antineoplastic drugs, environmental monitoring should be carried out. Wipe samples, pads, gloves and air samples should be collected at the end of each work shift, properly treated and then ana

Fully automated determination of eserine
✍ Pruvost, A.; Ragueneau, I.; Ferry, A.; Jaillon, P.; Grognet, J.-M.; Benech, H. 📂 Article 📅 2000 🏛 John Wiley and Sons 🌐 English ⚖ 109 KB 👁 2 views

A sensitive and entirely automated solid-phase extraction/liquid chromatography/electrospray ionization tandem mass spectrometric (SPE/LC/ESI-MS/MS) method was developed and validated for the determination of eserine N -oxide (ENO), a cholinesterase inhibitor-like physostigmine in human plasma, for

A simple liquid–liquid extraction with h
✍ Yuan-Qing Xia; Daisy B. Whigan; Mohammed Jemal 📂 Article 📅 1999 🏛 John Wiley and Sons 🌐 English ⚖ 246 KB 👁 2 views

Four sensitive, specific and accurate methods, based on high-performance liquid chromatography (HPLC) with positive ion electrospray tandem mass spectrometry (MS/MS) coupled with liquid-liquid extraction (LLE), have been developed and validated for the low-picogram determination of two drug candidat

High-performance liquid chromatography t
✍ Cristina Sottani; Claudio Minoia; Maurizio D'Incalci; Massimiliano Paganini; Mas 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 88 KB 👁 2 views

A sensitive, specific, accurate and reproducible analytical method was developed and validated for the quantitation of the anticancer agent paclitaxel in human plasma. This procedure is based on high performance liquid chromatography/ion spray -tandem mass spectrometry. This methodology is highly sp