๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Determination of methotrexate in environmental samples by solid phase extraction and high performance liquid chromatography: ultraviolet or tandem mass spectrometry detection?

โœ Scribed by Roberta Turci; Giuseppina Micoli; Claudio Minoia


Publisher
John Wiley and Sons
Year
2000
Tongue
English
Weight
126 KB
Volume
14
Category
Article
ISSN
0951-4198

No coin nor oath required. For personal study only.

โœฆ Synopsis


In order to assess exposure levels of hospital personnel involved in the preparation and administration of antineoplastic drugs, environmental monitoring should be carried out. Wipe samples, pads, gloves and air samples should be collected at the end of each work shift, properly treated and then analysed using instrumental techniques which are sufficiently sensitive and specific to detect even trace amounts of drug. In this study, a method using high performance liquid chromatography/tandem mass spectrometry (HPLC/ MS/MS), incorporating solid phase extraction (SPE), was validated for determination of methotrexate (MTX) in wipe and air samples. Each step of the method was first developed and optimised using ultraviolet detection (UV), and afterwards tandem mass spectrometry was used to obtain a lower limit of quantitation when the expected drug level was less than the analytical UV detection limit. SPE enabled a 20-fold preconcentration of the analyte when using HPLC/UV and a further 30-fold preconcentration was obtained when analysing samples by HPLC/MS/MS. For example, the limit of quantitation (LLQ) was lowered from 3000 ng on wipe (direct injection onto an HPLC/UV system) to 5 ng on wipe (SPE plus HPLC/MS/MS). 7hydroxymethotrexate was used as internal standard to assess precision and accuracy.


๐Ÿ“œ SIMILAR VOLUMES


Determination of methotrexate in human u
โœ Roberta Turci; Maria Lorena Fiorentino; Cristina Sottani; Claudio Minoia ๐Ÿ“‚ Article ๐Ÿ“… 2000 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 191 KB ๐Ÿ‘ 2 views

For biological monitoring of hospital personnel occupationally exposed to antineoplastic agents, highly sensitive and specific methods are required. In order to detect trace MTX urinary concentrations, a precise and accurate high-performance liquid chromatography/tandem mass spectrometry (HPLC-MS/MS

Rapid and sensitive determination of pac
โœ C. Sottani; R. Turci; G. Micoli; M. L. Fiorentino; C. Minoia ๐Ÿ“‚ Article ๐Ÿ“… 2000 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 114 KB ๐Ÿ‘ 1 views

A new, rapid and sensitive method for the quantitative determination of paclitaxel (Taxol(R)) in environmental samples is developed and validated. This highly sensitive and specific method was successfully applied to an environmental monitoring study for identifying occupational exposure situations

Liquidโ€“liquid extraction procedure for t
โœ Cristina Sottani; Roberta Turci; Luigi Perbellini; Claudio Minoia ๐Ÿ“‚ Article ๐Ÿ“… 1998 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 132 KB ๐Ÿ‘ 2 views

A sensitive, specific and accurate high performance liquid chromatography/ionspray-tandem mass spectrometry procedure (HPLC/MS/MS) has been developed to quantify cyclophosphamide in human urine from hospital personnel involved in drug preparation and administration of antineoplastic alkylating agent

High-performance liquid chromatography t
โœ Cristina Sottani; Claudio Minoia; Maurizio D'Incalci; Massimiliano Paganini; Mas ๐Ÿ“‚ Article ๐Ÿ“… 1998 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 88 KB ๐Ÿ‘ 2 views

A sensitive, specific, accurate and reproducible analytical method was developed and validated for the quantitation of the anticancer agent paclitaxel in human plasma. This procedure is based on high performance liquid chromatography/ion spray -tandem mass spectrometry. This methodology is highly sp

Rapid determination of methotrexate in p
โœ Samy Emara; Hassan Askal; Tsutomu Masujima ๐Ÿ“‚ Article ๐Ÿ“… 1998 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 66 KB ๐Ÿ‘ 1 views

A high-performance liquid chromatographic system, combining solid-phase extraction and automated precolumn derivatization is described for the routine determination of methotrexate in human plasma. The sample extraction and elution onto the analytical column were performed automatically and concomit

Quantitative determination of E5880 in r
โœ Kikuchi, Kiyomi; Sano, Yoshihisa; Taniguchi, Sachie; Matsui, Kenji; Namiki, Masa ๐Ÿ“‚ Article ๐Ÿ“… 1999 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 130 KB ๐Ÿ‘ 1 views

A simple and sensitive method is described for the determination of E5880 in rat plasma. The method is based on high-performance liquid chromatography/electrospray ionization mass spectrometry, using deuterated E5880 as an internal standard. Selected reaction monitoring is employed for selectivity a