โœฆ Synopsis


A combination of electrospray ionization, high-field asymmetric waveform ion mobility spectrometry, and mass spectrometry (ESI-FAIMS/MS) was used to analyze standard solutions of microcystins-LR, -RR, and -YR. The ability of FAIMS to separate ions in the gas phase reduced the amount of background in the mass spectrum without compromising the absolute signal for these microcystins. This reduction in background resulted in a ten-fold improvement in the signal-to-background ratio over conventional ESI-MS. Detection limits, using direct infusion, were determined to be 4, 2, and 1 nM for microcystins-LR, -RR, and -YR, respectively.


๐Ÿ“œ SIMILAR VOLUMES


Analysis of a commercial preparation of
โœ Chien-Chen Lai; Pei-Lun Tsai; Cheng Yu; Guor-Rong Her ๐Ÿ“‚ Article ๐Ÿ“… 2000 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 114 KB ๐Ÿ‘ 2 views

Because of the lack of a UV chromophore and their much smaller abundances in comparison with the major component, the minor components in erythromycin estolate preparations are difficult to analyze by high performance liquid chromatography ultraviolet (HPLC-UV). Tentative assignment of the major and

Quantitative determination of DNA adduct
โœ Siethoff, Christoph; Feldmann, Ingo; Jakubowski, Norbert; Linscheid, Michael ๐Ÿ“‚ Article ๐Ÿ“… 1999 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 147 KB ๐Ÿ‘ 2 views

The quantitative determination of nucleotides from DNA modiรed by styrene oxide is described using a combination of inductively coupled plasma high-resolution mass spectrometry (ICP-HRMS) and electrospray ionization mass spectrometry (ESI-MS), both interfaced to reversed-phase high-performance liqui

Capillary electrophoresis/electrospray i
โœ Ping Cao; Mehdi Moini ๐Ÿ“‚ Article ๐Ÿ“… 1998 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 151 KB ๐Ÿ‘ 2 views

Capillary electrophoresis/electrospray ionization (CE/ESI) high mass accuracy time-of-flight mass spectrometry was used for the first time to characterize small proteins using peptide mapping. To identify small proteins, the intact proteins were first analyzed to obtain their average molecular weigh

Determination of non-covalent metal ion-
โœ Kenneth L. Johnson; Timothy D. Veenstra; Andy J. Tomlinson; Rajiv Kumar; Stephen ๐Ÿ“‚ Article ๐Ÿ“… 1997 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 126 KB ๐Ÿ‘ 1 views

Figure 3. Deconvoluted spectra of rat brain calbindin D 28K showing (A) the apoprotein and (B) the holoprotein showing four calcium bound.