𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Dean vortex stability using magnetic resonance flow imaging and numerical analysis

✍ Scribed by Hanuman Mallubhotla; Georges Belfort; William A. Edelstein; Thomas A. Early


Publisher
American Institute of Chemical Engineers
Year
2001
Tongue
English
Weight
500 KB
Volume
47
Category
Article
ISSN
0001-1541

No coin nor oath required. For personal study only.


πŸ“œ SIMILAR VOLUMES


Reproducibility of total cerebral blood
✍ Aart Spilt; Frieke M.A. Box; Rob J. van der Geest; Johan H.C. Reiber; Patrik Kun πŸ“‚ Article πŸ“… 2002 πŸ› John Wiley and Sons 🌐 English βš– 89 KB

## Purpose: To evaluate reproducibility of total cerebral blood flow (cbf) measurements with phase contrast magnetic resonance imaging (pcmri). ## Materials and methods: We repeated total cbf measurements in 15 healthy volunteers with and without cardiac triggering, and with and without repositio

Quality control for functional magnetic
✍ Andrew Simmons; Elizabeth Moore; Steven C.R. Williams πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons 🌐 English βš– 124 KB πŸ‘ 1 views

A data acquisition and analysis protocol for quality control (QC) of functional magnetic resonance imaging studies is presented. Two sets of data are acquired, single-timepoint data for measurement of signal-to-ghost and signal-to-noise ratios, and multipletimepoint data for measurement of short-ter

In Vivo measurement of cerebral oxygen c
✍ J. Pekar; L. Ligeti; Z. Ruttner; R. C. Lyon; T. M. Sinnwell; P. van Gerderen; D. πŸ“‚ Article πŸ“… 1991 πŸ› John Wiley and Sons 🌐 English βš– 390 KB

## Abstract We used ^17^O NMR imaging techniques to measure the H~2~^17^O concentration in a 0.8‐ml voxel in the cat brain following injection of an arterial bolus of enriched H~2~^17^O and during inhalation of enriched ^17^O~2~. We also measured the H~2~^17^O concentration in arterial blood during

An analysis of the integration between a
✍ Sharan Ramaswamy; Dong-An Wang; Kenneth W. Fishbein; Jennifer H. Elisseeff; Rich πŸ“‚ Article πŸ“… 2006 πŸ› John Wiley and Sons 🌐 English βš– 238 KB

## Abstract A hydrogel is a highly hydrated polymer gel suitable for use as a scaffold for tissue engineering. One important application is to the repair of cartilage defects due to injury or osteoarthritis. Integration of the hydrogel with surrounding tissue is critical for the long‐term functiona

In vivo assessment of myocardial blood f
✍ Isabelle Iltis; Frank Kober; Christiane Dalmasso; Carole Lan; Patrick J. Cozzone πŸ“‚ Article πŸ“… 2005 πŸ› John Wiley and Sons 🌐 English βš– 310 KB

## Abstract ## Purpose To assess the influence of isoflurane and pentobarbital anesthesia and the carrier gases on myocardial blood flow (MBF) in the rat heart in vivo. ## Materials and Methods MBF was quantified in vivo using arterial spin‐labeling (ASL) magnetic resonance imaging (MRI). Left v