## Abstract Corrosion fatigue and fatigue properties of weld‐bonded and spot‐welded austenitic stainless steels EN 1.4301 and EN 1.4318 in 2B or 2F and 2H conditions were investigated. The corrosive environment was 3.5% NaCl solution at + 50 °C. In air the fatigue strengths of the weld‐bonded singl
Corrosion fatigue of spot-welded austenitic stainless steels in 3.5% NaCl solution
✍ Scribed by M. E. Somervuori; M. T. Alenius; H. E. Hänninen; R. Karppi
- Publisher
- John Wiley and Sons
- Year
- 2004
- Tongue
- German
- Weight
- 611 KB
- Volume
- 55
- Category
- Article
- ISSN
- 0947-5117
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Corrosion fatigue and fatigue properties of spot‐welded austenitic stainless steels EN 1.4301 and EN 1.4318 in 2B or 2F and 2H conditions were investigated in 3.5% sodium chloride (NaCl) solution and in air. The shear‐loaded specimens were single spot overlap joints.
The effect of steel grade, load, frequency, temperature and type of chloride on fatigue strength of the 1.0 mm thick steel specimens was evaluated by using the Taguchi Method®. Increase of the load, rise of temperature and lowering of the frequency accelerate corrosion fatigue of the spot‐welded steel samples. Type of chloride had only a minor effect on fatigue strength. The 2B grade spot‐welded steel samples exhibited better fatigue strength than the 2H grade samples of the same steels.
On the basis of the results obtained by the Taguchi Method® the S‐N curves were defined for the spot‐welded 1.9 mm thick steels in 3.5% sodium chloride solution at 50°C. For reference the fatigue experiments were performed in air at the ambient temperature. Comparison of the results shows that corrosive environment decreases remarkably the fatigue strength of the spot‐welded steels. The EN 1.4301 2H and EN 1.4318 2H steels have no distinctive difference in their corrosion fatigue strength even though they show a different fatigue behaviour in air.
The microscopic investigations indicate that the fatigue cracks in the spot welds initiate from either side of the recrystallised area in the HAZ outside the spot‐weld nugget both in air and in the corrosive environments. Pre‐exposure in the corrosive environment seems to have no major influence on the crack initiation, because the cracks do not initiate at the heat‐tinted area of the crevice where the crevice corrosion occurs.
📜 SIMILAR VOLUMES
## Abstract The corrosion resistance of spot‐welded and induction‐heated austenitic stainless steels EN 1.4301 and EN 1.4318 was investigated in 3.5% sodium chloride solution at ambient temperature. In potentiostatic measurements pitting corrosion of spot‐welded and induction‐heated samples occurs
## Abstract Mechanical and corrosion properties of spot‐welded high‐strength austenitic stainless steels EN 1.4318 2H/C1150 and EN 1.4318 2H/C850 were studied. Microhardness measurements, lap shear and cross‐tension tests, corrosion fatigue tests and corrosion tests were carried out. The corrosion
## Abstract Fatigue tests conducted both in air and synthetic physiological solution show that the fatigue strength of surgical stainless steel in synthetic physiological solution is about 10% lower than the strength in air for a given endurance level. It is proposed that surgical stainless steel w
## Abstract A literature survey has lead to the conclusion that a theory which postulates an increased anodic reactivity on a local site in the passive film is very probable. Experiments have been set up to confirm these suggestions. By means of the electron‐microanalyser, it is shown that CI^−^ion