## Abstract Corrosion fatigue and fatigue properties of weldβbonded and spotβwelded austenitic stainless steels EN 1.4301 and EN 1.4318 in 2B or 2F and 2H conditions were investigated. The corrosive environment was 3.5% NaCl solution at +Β 50βΒ°C. In air the fatigue strengths of the weldβbonded singl
Corrosion fatigue of surgical stainless steel in synthetic physiological solution
β Scribed by Cahoon, J. R. ;Holte, Richard N.
- Publisher
- John Wiley and Sons
- Year
- 1981
- Tongue
- English
- Weight
- 477 KB
- Volume
- 15
- Category
- Article
- ISSN
- 0021-9304
No coin nor oath required. For personal study only.
β¦ Synopsis
Abstract
Fatigue tests conducted both in air and synthetic physiological solution show that the fatigue strength of surgical stainless steel in synthetic physiological solution is about 10% lower than the strength in air for a given endurance level. It is proposed that surgical stainless steel which is normally passive in physiological solution suffers corrosion fatigue because of susceptibility to crevice corrosion which occurs at extrusions and intrusions (crevices) on the surface thereby shortening the crack initiation time and the fatigue life.
π SIMILAR VOLUMES
## Abstract Galvanic anodic protection (GAP) of stainless steels by doped polypyrrole (PPy) was investigated using chemically synthesized PPy. Separate PPy powderβpressed electrodes with different surface areas were prepared. Electrochemical properties of PPy electrodes were studied by open circuit
## Abstract The adequacy of 7 parameters of potentiokinetic curves for evaluating the resistance to pitting corrosion in sodium chloride solutions was quantitatively assessed by reference to immersion testing in ferric chloride solutions for 11 type CrNi (MoTiCu) stainless steels on the basis of 31
## Abstract The inhibition effect of the extract of galbanum (__Ferula gummosa__ Boiss.) on the corrosion of 304 stainless steel in 2 M HCl solution was studied by weight loss measurements, Tafel polarization, and electrochemical impedance spectroscopy (EIS) methods. It was found that the inhibitio
The localised corrosion resistance (pitting and crevice corrosion) of two high alloy stainless steels, namely superduplex (SD) and superaustenitic (SA), has been studied in chloride-fluoride solutions at pH values ranging from 2 to 6.5. The pitting potential (E pit ) and crevice potential (E cre ) h