Two previously unreported sources of systematic error in electrokinetic injection caused by induced (hydrodynamic) flow in sheathless capillary electrophoresis/electrospray have been characterized for an interface constructed from 5 pm i.d. capillary column(s) with a 2-5 pm i.d. electrospray tip(s).
Construction and characterization of a small-bore electrospray ionization source
β Scribed by Norman Sproch; Terry Kruger
- Publisher
- Elsevier Science
- Year
- 1993
- Tongue
- English
- Weight
- 353 KB
- Volume
- 4
- Category
- Article
- ISSN
- 1044-0305
No coin nor oath required. For personal study only.
β¦ Synopsis
A simple, economical, and efficient electrospray ionization (ESI) source has been constructed in the configuration of a probe that makes use of a standard 13 mm vacuum lock. The principal components have been placed inside a glass tube making use of the electrical insulating properties of the glass while allowing for visual adjustments to be readily made. The ESI source, a variation of an atmospheric pressure ionization interface, is a modified version of designs published by Chait et al. (Rapid Comm. Mass Spectrom. 1990, 4, 81-87) and Knapp et al. (Annl. Chem. 1991, 63, 1658-1660) wherein a heated metal capillary is used for desolvation. The ESI probe has been tested on three different Extrel quadmpole mass spectrometers, with removable ion volumes, using polypeptides and small proteins. No modifications to the standard electron ionization/chemical ionization lens assembly were required to obtain excellent results other than removal of the ion volume. The spectra acquired were in excellent agreement with those previously published.
π SIMILAR VOLUMES
In this work we describe a micro-electrospray ionization source equipped with an atmospheric pressure external ion shutter. The solenoid-activated shutter prevents the electrospray plume from entering the inlet capillary unless triggered to the 'open' position. When in the 'closed' position, a stabl
A method using reversed phase high performance liquid chromatography/electrospray ionization-mass spectrometry (RP-LC/ESI-MS) has been developed to confirm the identity of dansylated derivatives of cysteine (C) and glutathione (GSH), and their respective dimers, cystine (CSSC) and glutathione disulf
An electrospray ionization (ESI) mass spectral characterization of eight substituted tris(dithiocarbamato)iron(III) complexes (Fe(III)(dtc) 3 ) and of the diethyldithiocarbamate (et 2 dtc) -, complexes of Mn(III), Cu(II), Ni(II), and Co(III) is presented. Use is made of the inherent electrochemical
Two recombinant proteins derived by thrombin cleavage of a fusion protein between glutathione-S-transferase and CP10 (Chemotactic protein 10 kDa) were seperated by C4 reversed-phase high-performance liquid chromatography (RP-HPLC). Both proteins were recognised by a polyclonal antibody to native CP1
Electrospray ionization (ESI) is nowadays the most important technique for on-line liquid chromatography/mass spectrometry (LC/MS) coupling. Di β erent ESI probe designs including the microESI and pneumatically assisted ESI (ionspray) interfaces allow the introduction of sample at Γow-rates ranging f