𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Comparison of test protocols for the standard room/corner test

✍ Scribed by Robert H. White; Mark A. Dietenberger; Hao Tran; Ondrej Grexa; Les Richardson; Kuma Sumathipala; Marc Janssens


Publisher
John Wiley and Sons
Year
1999
Tongue
English
Weight
133 KB
Volume
23
Category
Article
ISSN
0308-0501

No coin nor oath required. For personal study only.

✦ Synopsis


As part of international e4orts to evaluate alternative reaction-to-5re tests, several series of room/corner tests have been conducted. Materials tested were mostly di4erent wood products but included gypsum board and a few foam plastics. This is a review of the overall results of related studies in which the di4erent test protocols for the standard room/corner test were used. Di4erences in the test protocols involved two options for the ignition burner scenario and whether or not the ceiling was also lined with the test materials. The test materials were placed on three walls of the room in all the tests. The two burner scenarios were (1) 40 kW for 300 s followed by 160 kW for 300 s and (2) 100 kW for 600 s and 300 kW for 600 s. The 40 and 160 kW burner scenario without the ceiling lined did not provide a severe enough test for 6ashover to occur with 5re-retardant-treated materials. Use of the 100 and 300 kW burner scenario without lining the ceiling provided the ability to di4erentiate between wood products with ASTM E 84 6ame spread indexes of 70 to 125 and those with higher 6ame spread indexes. Lining the ceiling with test material creates a more severe test.


πŸ“œ SIMILAR VOLUMES


Empirical prediction of smoke production
✍ Atle William Heskestad; Per Jostein Hovde πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons 🌐 English βš– 116 KB πŸ‘ 1 views

The combustion conditions in the ISO Room Corner Fire Test make it possible to predict full scale smoke production by use of prediction models and bench scale 5re test data procured by the ISO Cone Calorimeter Fire Test. The full scale smoke production is governed by the type of material burning onl

Comparison of different test methods for
✍ G. Wagner; M. Osterhold πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons 🌐 English βš– 180 KB πŸ‘ 1 views

This paper presents a number of different methods for determining the mar resistance of automotive clearcoats. The various methods are compared on the basis of measurements on different clearcoat systems and the results discussed with other physical parameters (microhardness, crosslinking density).

A comparison of electrophysiological tes
✍ Carlos Pastore; Virginia Izura; Emilio Geijo-Barrientos; Jose-Ramon Dominguez πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons 🌐 English βš– 143 KB πŸ‘ 1 views

Clinical criteria and several electrophysiological parameters for detecting nerve damage were compared in 99 patients with diabetes mellitus type 1 and type 2. Abnormal results were found in sural/radial amplitude ratio (51%), minimal F-wave latency of the tibial nerve (36.4%), sensory conduction ve

A COMPARISON OF GOODNESS-OF-FIT TESTS FO
✍ D. W. HOSMER; T. HOSMER; S. LE CESSIE; S. LEMESHOW πŸ“‚ Article πŸ“… 1997 πŸ› John Wiley and Sons 🌐 English βš– 271 KB πŸ‘ 2 views

Recent work has shown that there may be disadvantages in the use of the chi-square-like goodness-of-fit tests for the logistic regression model proposed by Hosmer and Lemeshow that use fixed groups of the estimated probabilities. A particular concern with these grouping strategies based on estimated

A comparison of neuropsychological tests
✍ Kai Γ–sterberg; Palle ØrbΓ¦k; BjΓΆrn Karlson; Ulf Bergendorf; Lena Seger πŸ“‚ Article πŸ“… 2000 πŸ› John Wiley and Sons 🌐 English βš– 170 KB

## Background: From the viewpoint of the clinical neuropsychologist, it is not evident if the detection of solvent induced toxic encephalopathy (te) could be optimized by a modification of the traditional test batteries, adding tests covering new dimensions or monitoring further functional domains.