Comparison of T2-weighted spin-echo and fast spin-echo techniques in the evaluation of myelination
✍ Scribed by Erin C. Prenger; William W. Beckett; Spyros S. Kollias; William S. Ball Jr
- Publisher
- John Wiley and Sons
- Year
- 1994
- Tongue
- English
- Weight
- 661 KB
- Volume
- 4
- Category
- Article
- ISSN
- 1053-1807
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
To evaluate T2‐weighted fast spin‐echo (FSE) and conventional spin‐echo (CSE) magnetic resonance (MR) techniques in the assessment of brain myelination, 100 consecutive pediatric patients were imaged prospectively with both CSE and FSE sequences. All patients underwent a routine MR examination that included T2‐weighted CSE imaging (imaging time, 10 minutes 21 seconds) and T2‐weighted FSE imaging (imaging time, 2 minutes 5 seconds). The two techniques were compared for estimating the degree of myelination (using normal anatomic landmarks) by blind review. With T2‐weighted CSE images as the “gold standard” for estimation of normal myelination, FSE images were evaluated to determine if they showed the degree of myelination similarly to CSE images. There was a strong correlation (P <.01) between CSE and FSE images in the estimation of myelination over a wide range of patient ages.
📜 SIMILAR VOLUMES
## Abstract ## Purpose To compare the abilities of T2‐weighted (T2W) imaging using respiratory‐triggered fast spin‐echo (RT‐FSE), breathhold fast‐recovery FSE (BH‐FRFSE), and BH single‐shot FSE (BH‐SSFSE) sequences without an endorectal coil to detect rectosigmoid carcinomas. ## Materials and Met
## Abstract In 49 patients who had pelvic abnormalities, breath‐hold T2‐weighted fast‐recovery (FR)‐fast spin‐echo (FSE) (imaging time = 24 sec) and nonbreath‐hold FSE MR images (2 min 8 sec) were compared qualitatively (on a four‐point scale) and quantitatively (using signal‐to‐noise ratios (SNRs)
## Abstract The purpose of our study was to compare the value of respiratory‐triggered fast spin‐echo, breath‐hold single‐shot fast spin‐echo, and breath‐hold fast‐recovery fast spin‐echo sequences in detecting hepatic lesions. Fat‐suppressed T2‐weighted magnetic resonance (MR) images obtained with
## Abstract Fast spin‐echo (FSE) pulse sequences enable T2‐weighted imaging in a fraction of the time required for T2‐weighted conventional spin‐echo (CSE) imaging. Due to concerns that the altered contrast characteristics of FSE may interfere with the visualization of multiple sclerosis (MS) lesio