## Abstract The applicability of liquid chromatography/tandem mass spectrometry (LC/MS/MS) for the detection of the free anabolic steroid fraction in human urine was examined. Electrospray ionization (ESI), atmospheric pressure chemical ionization and atmospheric pressure photoionization methods we
Comparison of electrospray ionization and atmospheric pressure chemical ionization techniques in the analysis of the main constituents from Rhodiola rosea extracts by liquid chromatography/mass spectrometry
✍ Scribed by Ari Tolonen; Anja Hohtola; Jorma Jalonen
- Publisher
- John Wiley and Sons
- Year
- 2003
- Tongue
- English
- Weight
- 182 KB
- Volume
- 38
- Category
- Article
- ISSN
- 1076-5174
- DOI
- 10.1002/jms.497
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Rhodiola rosea L. (Golden Root) has been used for a long time as an adaptogen in Chinese traditional medicine and is reported to have many pharmacological properties. A liquid chromatographic (LC) method with mass spectrometric (MS) detection based on selected ion monitoring (SIM) was developed for determining salidroside, sachaliside 1, rosin, 4‐methoxycinnamyl‐O‐β‐glucopyranoside, rosarin, rosavin, cinnamyl‐(6′‐O‐β‐xylopyranosyl)‐O‐β‐glucopyranoside, 4‐methoxy‐cinnamyl‐(6′‐O‐α‐arabinopyranosyl)‐O‐β‐glucopyranoside, rosiridin and benzyl‐O‐β‐glucopyranoside from the callus and plant extracts in one chromatographic run. Good linearity over the range 0.5–500 ng ml^−1^ for salidroside, 2–2000 ng ml^−1^ for rosavin and 2–500 ng ml^−1^ for benzyl‐O‐β‐glucopyranoside was observed. The intra‐assay accuracy and precision within quantitation ranges varied between −10.0 and +13.2% and between 0.7 and 9.0%, respectively. Optimization of the ionization process was performed with electrospray and atmospheric pressure chemical ionization techniques using four different additive compositions for eluents in the LC/MS scan mode, using both positive and negative ion modes. The best ionization sensitivity for the compounds studied was obtained with electrospray ionization when using pure water without any additives as the aqueous phase. Copyright © 2003 John Wiley & Sons, Ltd.
📜 SIMILAR VOLUMES
Capillary liquid chromatography/mass spectrometry (LC/MS) is usually performed using electrospray ionization. Atmospheric pressure chemical ionization (APCI) has not been used since the flow rates involved (1-10 µL/min) are too low to effect ionization with a standard APCI source. Using a 320 µm ؋ 1
We report the new application of negative ion atmospheric pressure chemical ionization (APCI) to the detection of composite bacteriohopanepolyols in bacterial and sedimentary (or other natural environmental) samples. The method employs the addition of dichloromethane to the high performance liquid c
## Abstract The major adduct of malondialdehyde with guanine, M~1~G, was measured in human urine from non‐smoking healthy individuals. M~1~G is a mutagenic DNA lesion and a terminal product of lipid peroxidation __in vivo__ that may be implicated in cancer related to lifestyle and diet. On the basi
Glyburide (glibenclamide) is widely prescribed in the treatment of Type II diabetes. A validated liquid chromatography atmospheric pressure chemical ionization tandem mass spectrometry (LC/APCI-MS/MS) method for the determination of glyburide is reported. The method uses a stable isotope labeled gly