𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Comparing monolithic and microparticular capillary columns for the separation and analysis of peptide mixtures by liquid chromatography-mass spectrometry

✍ Scribed by Hansjörg Toll; Reiner Wintringer; Ulrike Schweiger-Hufnagel; Christian G. Huber


Publisher
John Wiley and Sons
Year
2005
Tongue
English
Weight
547 KB
Volume
28
Category
Article
ISSN
1615-9306

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

A mixture of ten proteins was trypsinized and injected onto poly‐(styrene‐divinylbenzene) monolithic columns (60×0.20 or 0.10 mm ID) and a column packed with C18 silica particles (75×0.075 mm ID), respectively. The columns were eluted at 200–2000 nL/min with gradients of ACN in 0.050% TFA. Eluting peptides were detected by ESI‐MS/MS and subsequently identified by database searching. The 100 μm ID monolithic column showed the highest cumulative Mowse scores based on the highest ion scores for the peptides and the largest number of identified peptides. It is shown that the number of identified peptides strongly depends on the dynamic range within the peptide mixture. In consequence, all proteins were identified in a mixture of relatively balanced analyte amounts (12.5–80 fmol) whereas only peptides for six out of ten proteins were found in a sample of high‐dynamic range (0.65–270 fmol). The 100 μm monolithic column showed the highest reproducibility for peptide identifications in three consecutive runs. Depending on sample amount, 57–72% of the identified peptides were detectable in each of the three runs of triplicate analyses. The results demonstrate the high suitability of 100 μm monolithic columns for high‐resolution peptide separations in proteomic research.


📜 SIMILAR VOLUMES


Separation and identification of peptide
✍ V. Sanz-Nebot; I. Toro; A. Garcés; J. Barbosa 📂 Article 📅 1999 🏛 John Wiley and Sons 🌐 English ⚖ 117 KB 👁 2 views

In order to separate and characterize the target peptide and the side-product peptide compounds of a synthesis crude of the peptide hormone carbetocin, liquid chromatography coupled to high-flow electrospray ionization mass spectrometry (LC/ES-MS) has been used. Carbetocin is an important drug with

Rapid separation and characterization of
✍ John E. MacNair; Gregory J. Opiteck; James W. Jorgenson; M. Arthur Moseley III 📂 Article 📅 1997 🏛 John Wiley and Sons 🌐 English ⚖ 249 KB 👁 1 views

Octadecyl-modified 1.5 µm diameter non-porous silica particles were packed in 150 µm i.d. (360 µm o.d.) capillaries with lengths of 20 cm which were used to separate proteins and peptides generated from enzymatic digests of proteins. Gradients were produced using an exponential dilution method at pr

Capillary liquid chromatography/electros
✍ Joseph J. Dalluge; Bryant C. Nelson; Jeanice B. Thomas; Michael J. Welch; Lane C 📂 Article 📅 1997 🏛 John Wiley and Sons 🌐 English ⚖ 102 KB 👁 2 views

The separation and detection of biologically active green tea catechins has been accomplished using capillary liquid chromatography/electrospray mass spectrometry (cLC/ESI-MS). Microscale determination ( ~20 ng) of all six catechins in a green tea infusion, and the most extensively studied catechin,