Combination sensor for measurement of light and temperature
β Scribed by A. J. Welch; C. P. Cain
- Publisher
- John Wiley and Sons
- Year
- 1995
- Tongue
- English
- Weight
- 305 KB
- Volume
- 16
- Category
- Article
- ISSN
- 0196-8092
No coin nor oath required. For personal study only.
β¦ Synopsis
METHODS Fabrication of Thermocouple-Light Probe
Standard 1 mm glass pipettes were drawn to an outer tip diameter of -50 pm and an interior diameter of -30 pm. An annular thermocouple junction was formed at the tip by vapor deposition of nickel and copper on the pipette. First, a 2,000
A nickel film was deposited on the tip and on one side of the pipette. The nickel was annealed and a nickel lead was attached to the side of the probe. The tip was placed against a mask and the probe of PaTlene c@* The mask was removed and a 2,000 copper film was deposited on the tip and non-nickel side of the probe. Following the attachment of a copper lead on the side of the pipette, sulation.
π SIMILAR VOLUMES
## Abstract Cryogenic temperature sensing has been demonstrated using Polymer coated Fiber Bragg Grating Sensor, and the experimental results are presented in this article. Teflon coating thicknesses of 20 and 40 ΞΌ applied on Fiber Bragg Gratings, inscribed in silica fiber (TFBG) are used for these
## Abstract An embedded dual fiber Bragg gratings sensor for simultaneous measurement of temperature and load (strain) is proposed and experimentally demonstrated. Two nearly identical gratings are mounted on opposite side of an archβshaped steel strip. The grating in concave and convex position ex