๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Clinical impact of a new automated system employed for peripheral blood stem cell collection

โœ Scribed by Claudia Del Fante; Cesare Perotti; Gianluca Viarengo; Laura Bellotti; Cristina Parisi; Andrea Marchesi; Carmine Tinelli; Laura Salvaneschi


Publisher
John Wiley and Sons
Year
2006
Tongue
English
Weight
165 KB
Volume
21
Category
Article
ISSN
0733-2459

No coin nor oath required. For personal study only.

โœฆ Synopsis


At the moment, PBSC collections can be performed using semi-automated or automated cell separator devices. The automated methods offer the advantages of a decreased working load for dedicated personnel and high standardization of the collection procedure. Herein we report our single institutional experience in 80 PBSC collections employing the new automated COM.TEC Fresenius autoMNC program that provides the ability to predict the total number of CD34+ cells collected, based on the pre-leukapheresis CD34+ cell count in peripheral blood. Fourty-eight patients and 21 healthy donors were mobilized with chemotherapy + G-CSF or G-CSF alone, respectively. Eighty leukapheresis collections were performed starting with a CD34+ cell count in peripheral blood at least of 20/lL. Collection parameters and related side effects were evaluated. The mean CD34+ cell collection efficiency in patients and donors was 81.8% (sd 27.6) and 95.1% (sd 15.6), respectively. The mean difference between real and predicted CD34+ cells was +30.2% (sd 92.9) for patients and +4.6% (sd 30.3) for donors. The mean leukapheresis bag volume was 240.7 ml (sd 67.3) and 310.3 ml (sd 86.8) with a mean HCT of 10.9% (sd 34.4) and 9.2% (sd 3.9) for patients and donors, respectively. The automated PBSC collection with the new program COM.TEC Fresenius autoMNC demonstrated a very high CD34+ cell collection efficiency. Moreover, the ability to predict the CD34+ cell yield permits improved management of the leukapheresis collection, with the only disadvantage of larger leukapheresis volume and higher hematocrit.


๐Ÿ“œ SIMILAR VOLUMES


Evaluation of a new protocol for periphe
โœ Giacomo Menichella; Marco Lai; Luca Pierelli; Riccardo Serafini; Mariangela Vitt ๐Ÿ“‚ Article ๐Ÿ“… 1997 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 67 KB ๐Ÿ‘ 2 views

In this report we analyzed sixty leukapheresis procedures on 35 patients with a new protocol for the Fresenius AS 104. Yields and efficiencies for MNC, CD 34+ cells, and CFU-GM indicate that the new protocol is able to collect large quantities of hemopoietic progenitors. Procedures were performed pr

A discrepancy between the instantaneous
โœ David N. Haylock; Ann Canty; Dawn Thorp; Pamela G. Dyson; Christopher A. Juttner ๐Ÿ“‚ Article ๐Ÿ“… 1992 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 509 KB

The collection efficiency (CE) of the Fenwall CS3000 continuous flow blood cell separator in the apheresis of peripheral blood stem cells during haemopoietic recovery following myelosuppressive chemotherapy was analysed. Ninety-three aphereses were performed in 19 patients using procedure 3 on the F

Feasibility of sequential high-dose chem
โœ Jakacki, Regina I.; Jamison, Cheryl; Heifetz, Stephen A.; Caldemeyer, Karen; Han ๐Ÿ“‚ Article ๐Ÿ“… 1997 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 58 KB ๐Ÿ‘ 2 views

Background. The outlook for many brain tumors remains poor. Increased dose intensity has been correlated with response rate and survival in many solid tumors. Patients and Methods. Ten children with recurrent or newly diagnosed brain tumors were treated with four sequential courses of highdose sing

Counterflow centrifugation apheresis for
โœ Harry C. Schouten; Anne Kessinger; Douglas M. Smith; James D. Landmark; Robert S ๐Ÿ“‚ Article ๐Ÿ“… 1990 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 438 KB

## Abstract Two apheresis methods used to collect hematopoietic stem cells from peripheral blood were compared in eight patients with a variety of malignancies. The standard lymphocyte collection method was alternated with the counterflow centrifugation or lymphocyte surge protocol. The number of c