𝔖 Bobbio Scriptorium
✦   LIBER   ✦

A discrepancy between the instantaneous and the overall collection efficiency of the fenwal CS3000 for peripheral blood stem cell apheresis

✍ Scribed by David N. Haylock; Ann Canty; Dawn Thorp; Pamela G. Dyson; Christopher A. Juttner; L. Bikto


Publisher
John Wiley and Sons
Year
1992
Tongue
English
Weight
509 KB
Volume
7
Category
Article
ISSN
0733-2459

No coin nor oath required. For personal study only.

✦ Synopsis


The collection efficiency (CE) of the Fenwall CS3000 continuous flow blood cell separator in the apheresis of peripheral blood stem cells during haemopoietic recovery following myelosuppressive chemotherapy was analysed. Ninety-three aphereses were performed in 19 patients using procedure 3 on the Fenwal CS3000. The overall CE was calculated from the pre-apheresis cell counts and the stated blood volume processed. Instantaneous CE was calculated from cell counts in the inlet and return lines. The overall mononuciear cell and granulocyte-macrophage colony forming unit CE were 64.0% and 55.8%, respectively, significantly lower than the instantaneous CEs of 94.5% and 95.4%, respectively ( P = 0.0001, t test, for both comparisons). Three factors unrelated to machine performance contributed to the lower overall CE despite a high instantaneous CE: (1) A fall in the patient's mononuclear cell counts during apheresis leading to an overestimation of the cells available for collection, (2) dilution of blood by anti-coagulant, and (3) the operational dead space of the Fenwal CS3000. The overall CE corrected for these 3 factors approximated the instantaneous CE closely. Thus there is little room for further enhancement of machine performance because the Fenwal CS3000 is already operating with a very high instantaneous CE. To achieve major improvement in the yield of peripheral blood stem cell harvests, more effective mobilization protocols and better timing of apheresis are required.


πŸ“œ SIMILAR VOLUMES


Concurrent comparison of the cobe spectr
✍ Doug Padley; Ronald G. Strauss; Martha Wieland; M. Joleen Randels πŸ“‚ Article πŸ“… 1991 πŸ› John Wiley and Sons 🌐 English βš– 305 KB

Hematopoietic stem cells, collected by leukapheresis from peripheral blood. can be used as an alternative to autologous bone marrow transplantation following high-dose chemotherapy as treatment of several malignancies. We compared the ability of the Cobe Spectra and the Fenwal CS3000 to collect peri

Collection efficiency on the fenwal CS30
✍ L. Bik To; German R. Stemmelin; David N. Haylock; Joanne L. Bayly; Dawn Thorp; C πŸ“‚ Article πŸ“… 1994 πŸ› John Wiley and Sons 🌐 English βš– 376 KB

## Abstract The collection efficiency (CE) of the Fenwal CS3000 in collecting peripheral blood stem cells during post‐chemotherapy recovery phase ranges from 58% to 73%. Recently filgrastim (recombinant methionyl human granulocyte colony‐stimulating factor [G‐CSF]) has also been shown to be effecti

Large-volume leukapheresis using femoral
✍ Sang Kyun Sohn; Jong Gwang Kim; Yeo Soo Chae; Dong Hwan Kim; Nan Young Lee; Jang πŸ“‚ Article πŸ“… 2003 πŸ› John Wiley and Sons 🌐 English βš– 91 KB πŸ‘ 1 views

## Abstract The current paper reports on the predicting factors associated with satisfactory peripheral blood stem cell collection and the efficacy of large‐volume leukapheresis (LVL) using femoral vein catheterization to harvest PBSCs with Fenwal CS 3000 Plus from normal healthy donors for allogen

Adjustment of the interface detector (lo
✍ J. W. Baars; W. J. Nooyen; C. van Beers; M. J. Holtkamp; A. te Velde; O. Dalesio πŸ“‚ Article πŸ“… 1997 πŸ› John Wiley and Sons 🌐 English βš– 37 KB πŸ‘ 2 views

Improvement of the collection efficiency (CE) of the Fenwal CS3000 plus in collecting circulating progenitor cells (CPC) might diminish the number of leukapheresis procedures (LP) required to obtain the CPC required to assure engraftment. We analyzed whether adjustment of the optical setting (locati

Counterflow centrifugation apheresis for
✍ Harry C. Schouten; Anne Kessinger; Douglas M. Smith; James D. Landmark; Robert S πŸ“‚ Article πŸ“… 1990 πŸ› John Wiley and Sons 🌐 English βš– 438 KB

## Abstract Two apheresis methods used to collect hematopoietic stem cells from peripheral blood were compared in eight patients with a variety of malignancies. The standard lymphocyte collection method was alternated with the counterflow centrifugation or lymphocyte surge protocol. The number of c

Evaluation of a new protocol for periphe
✍ Giacomo Menichella; Marco Lai; Luca Pierelli; Riccardo Serafini; Mariangela Vitt πŸ“‚ Article πŸ“… 1997 πŸ› John Wiley and Sons 🌐 English βš– 67 KB πŸ‘ 2 views

In this report we analyzed sixty leukapheresis procedures on 35 patients with a new protocol for the Fresenius AS 104. Yields and efficiencies for MNC, CD 34+ cells, and CFU-GM indicate that the new protocol is able to collect large quantities of hemopoietic progenitors. Procedures were performed pr