## Abstract In this paper, a method was described to determine cocaine (COC) and benzoylecgonine (BZE) in human urine samples by GC‐MS detection. The extraction of analytes from urine samples was achieved in an Oasis hydrophilic–lipophilic balance column (20 mm×3.9 mm id, dp=25 μm; Waters, USA), in
Chiral analysis by mass spectrometry using the kinetic method in flow systems
✍ Scribed by Karel Lemr; Václav Ranc; Petr Fryčák; Petr Bednář; Juraj Ševčík
- Publisher
- John Wiley and Sons
- Year
- 2006
- Tongue
- English
- Weight
- 262 KB
- Volume
- 41
- Category
- Article
- ISSN
- 1076-5174
- DOI
- 10.1002/jms.1008
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Chiral analysis is an important task of analytical chemistry. Besides separation techniques, mass spectrometry can be applied in this field. One mass spectrometric approach is based on Cooks' kinetic method. The method was successfully applied in a static system in which the concentration of the analyte as well as the chiral selector solution was constant during the experiment. The application of the kinetic method in dynamic systems (changing concentration of analyte) is presented. Such systems allow the speeding up of the analytical process (flow injection analysis (FIA)) or the use of the kinetic method for chiral detection after liquid chromatographic separation.
The influence of the concentration of the components of the chiral selector solution as well as its flow rate on the recognition of enantiomers was evaluated. A new procedure for correction for the differences between ratio of enantiomers in the liquid phase and their observed ratio in the gas phase is also described. A significant improvement in accuracy using this procedure was achieved. Applicability of the method was demonstrated in the analysis of amino acids using FIA as well as HPLC/MS. After an achiral separation of leucine and isoleucine, chiral mass spectrometric detection was successfully used for enantiomeric recognition. Copyright © 2006 John Wiley & Sons, Ltd.