A method was developed for the analysis and characterization of quercetin and kaempferol in urine following ingestion of Ginkgo biloba tablets. The method utilized gas chromatography/negative ion chemical ionization mass spectrometry of the trimethysilyl derivatives of the flavonoids. Limits of dete
Analysis of cocaine and benzoylecgonine in urine by using multisyringe flow injection analysis-gas chromatography-mass spectrometry system
✍ Scribed by María del Rosario Brunetto; Yelitza Delgado; Sabrina Clavijo; Yaritza Contreras; Dina Torres; Carlos Ayala; Máximo Gallignani; Rafael Forteza; Víctor Cerdà Martin
- Publisher
- John Wiley and Sons
- Year
- 2010
- Tongue
- English
- Weight
- 212 KB
- Volume
- 33
- Category
- Article
- ISSN
- 1615-9306
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
In this paper, a method was described to determine cocaine (COC) and benzoylecgonine (BZE) in human urine samples by GC‐MS detection. The extraction of analytes from urine samples was achieved in an Oasis hydrophilic–lipophilic balance column (20 mm×3.9 mm id, dp=25 μm; Waters, USA), incorporated in a multisyringe flow injection system, used for the sample treatment. Finally, to improve the volatility of the BZE, an in‐line derivatization reaction with N,O‐bis (trimethylsilyl) trifluoroacetamide with 1% trimethylchlorosilane was made microwave‐assisted in order to reduce the reaction time. The results showed that the proposed method is a good alternative for the analysis of COC and BZE in urine samples because it offers advantages compared with those described in the literature, which include simplicity in the sample treatment, the sensitivity and selectivity necessary to determine the analytes of interest at low levels in the urine and high sample throughput.
📜 SIMILAR VOLUMES
A detailed procedure for the analysis of exogenous dehydroepiandrosterone (DHEA) in urine by gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS) has been established for detecting doping with DHEA. The average d -value (parts per thousand difference of 13 C/ 12 C ratio from the
Although gas chromatography/mass spectrometry (GC/MS) is the most powerful technique for analysing cocaine and its hydrolysis products (benzoylecgonine, ecgonine methyl ester and ecgonine) in urine, the sample pretreatment required is rather laborious and involves a large number of steps. This paper
Adult male volunteers were administered orally 10 mg of the respective drug. Urine samples were investigated by microcolumn liquid chromatography and capillary gas chromatography combined with on-line mass spectrometry. The former technique was found to be usable for the detection of these drugs. Th