𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Chemical mass shifts in resonance ejection experiments in the quadrupole ion trap

✍ Scribed by Hongyan Li; Wolfgang R. Plass; Garth E. Patterson; R. Graham Cooks


Publisher
John Wiley and Sons
Year
2002
Tongue
English
Weight
235 KB
Volume
37
Category
Article
ISSN
1076-5174

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Chemical mass shifts were measured in a Paul ion trap operated in the mass‐selective instability scan with resonance ejection using a custom‐built instrument. These shifts, which can be as much as 2%, decrease with increasing endcap electrode separation owing to changes in the higher order contributions to the electric field. They also decrease with decreasing helium buffer gas pressure. Both of these effects are analogous to those found with boundary ejection. This suggests that the previously proposed chemical mass shift mechanism based on compound‐dependent collisional modification of the ejection delay produced by field faults near the endcap electrode apertures holds true also for resonance ejection. The influence of the resonance frequency on chemical mass shifts was also investigated and it is shown that at certain working points (values of the Mathieu parameter q~z~ and a~z~) non‐linear resonances greatly reduce the ejection delay for all ions, regardless of their chemical structures, and thus reduce the magnitude of the chemical mass shift. Energetic collisions leading to dissociation can take place at an earlier stage during the ejection process in the mass analysis scan when using resonance ejection compared with boundary ejection. This leads to even larger chemical mass shifts of fragile ions in resonance ejection. Increasing the resonance voltage amplitude can enhance this effect. The chemical mass shifts of fragile ions increase with increase in the resonance voltage amplitude, whereas negligible changes occur for structurally stable ions. Copyright Β© 2002 John Wiley & Sons, Ltd.


πŸ“œ SIMILAR VOLUMES


Origin of mass shifts in the quadrupole
✍ James Patrick Murphy III; Richard A. Yost πŸ“‚ Article πŸ“… 2000 πŸ› John Wiley and Sons 🌐 English βš– 48 KB πŸ‘ 2 views

A novel hybrid tandem mass analyzer, coupling a quadrupole ion trap with a quadrupole mass filter, has been constructed to permit mass analysis of ions ejected from the ion trap. The initial application of this instrument is the investigation of the origin of mass shifts in the ion trap due to ion f

Simplified electron ejection in Fourier
✍ Brian T. Cooper; Steven W. Buckner πŸ“‚ Article πŸ“… 1993 πŸ› John Wiley and Sons 🌐 English βš– 567 KB

Suspended trapping is used to eject electrons in negative-ion Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometric experiments. In contrast to electron ejection by resonant excitation of the trapping motion, suspended trapping involves allowing the electrons to escape along the z-ax

Low-energy ionization of hydrocarbons in
✍ Stilianos G. Roussis; W. Patrick Fitzgerald; Andrew S. Cameron πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 274 KB πŸ‘ 2 views

The capabilities of a commercial ion trap mass spectrometer to readily perform chemical ionization experiments have been exploited to account for the restrictions of the instrument to perform low-energy ($10 eV) electron ionization (EI) experiments. CS 2 and benzene have been used as representative

Investigation of the Mass Shifts Caused
✍ Wenjun Mo; John F. J. Todd πŸ“‚ Article πŸ“… 1996 πŸ› John Wiley and Sons 🌐 English βš– 479 KB πŸ‘ 2 views

An ion-coupling model has been proposed to predict and interpret the occurrence of mass shifts induced by the presence of ions of other m/z ratios in the ion trap mass spectrometer. The method of dynamically scanning the dipolar tickle frequency has been used to determine the mass shifts for two spe

Solvation of acylium fragment ions in el
✍ Ziqiang Guan; Jerrold M. Liesch πŸ“‚ Article πŸ“… 2001 πŸ› John Wiley and Sons 🌐 English βš– 330 KB

## Abstract In electrospray ionization (ESI) quadrupole ion trap and Fourier transform ion cyclotron resonance mass spectrometry, certain fragment ions (e.g. acylium ions) generated either during the ion transportation process (in the source interface region) or in the ion trap are found to undergo