๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Low-energy ionization of hydrocarbons in the quadrupole ion trap mass spectrometer

โœ Scribed by Stilianos G. Roussis; W. Patrick Fitzgerald; Andrew S. Cameron


Publisher
John Wiley and Sons
Year
1998
Tongue
English
Weight
274 KB
Volume
12
Category
Article
ISSN
0951-4198

No coin nor oath required. For personal study only.

โœฆ Synopsis


The capabilities of a commercial ion trap mass spectrometer to readily perform chemical ionization experiments have been exploited to account for the restrictions of the instrument to perform low-energy ($10 eV) electron ionization (EI) experiments. CS 2 and benzene have been used as representative reagent compounds for low-energy ionization by charge exchange in the ion trap with the main objective being the production of mass spectra of hydrocarbon compounds with intense peaks in the molecular ion region. n-Pentane was used as a representative small alkane reagent compound to investigate its capability to form intense peaks of molecular ion species in the spectra of saturated hydrocarbons. No intense peaks were produced in the molecular ion region, by any of the three reagents, for the mass spectra of model linear saturated hydrocarbons. The relatively weak stability of these compounds and the excess amounts of internal energy supplied by the various dynamic processes in the ion trap may partly account for the increased fragmentation. Intense molecular ion species and fragment ion peaks were observed in the mass spectra of cyclic saturated hydrocarbons. Charge exchange of aromatic compounds with CS 2 and benzene produced mass spectra with intense molecular ion peaks and limited fragmentation, similar to the mass spectra obtained in conventional mass spectrometers. The methods developed in this study were used for the analysis of typical middle distillate and heavy petroleum samples.


๐Ÿ“œ SIMILAR VOLUMES


Ion-molecule reactions of dimethyl ether
โœ Mosi, Andrew A.; Skelton, Randall H.; Eigendorf, Guenter K. ๐Ÿ“‚ Article ๐Ÿ“… 1999 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 72 KB ๐Ÿ‘ 2 views

The reaction chemistry between dimethyl ether (DME) cations and polycyclic aromatic hydrocarbons (PAHs) was elucidated by isolating three different types of DME ions using a quadrupole ion trap and reacting them individually with neutral PAH molecules eluting from a gas chromatographic column. The r

Gas phase hydrogen/deuterium exchange re
โœ Igor A. Kaltashov; Vladimir M. Doroshenko; Robert J. Cotter ๐Ÿ“‚ Article ๐Ÿ“… 1997 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 93 KB ๐Ÿ‘ 2 views

Hydrogen/deuterium exchange reactions of protonated and sodium cationized peptide molecules have been studied in the gas phase with a MALDI / quadrupole ion trap mass spectrometer. Unit-mass selected precursor ions were allowed to react with deuterated ammonia introduced into the trap cell by a puls

Theoretical and numerical analysis of th
โœ Kiyomi Yoshinari ๐Ÿ“‚ Article ๐Ÿ“… 2000 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 239 KB ๐Ÿ‘ 2 views

A numerical simulation method has been developed for the analysis of trapping ions injected into an ion trap mass spectrometer. This method was applied to clarify the effects of the following parameters on trapping efficiencies: (1) initial phase of the radio frequency (RF) drive voltage, (2) ion in

Electrospray ionization tandem mass spec
โœ Jehuda Yinon; Joseph E. McClellan; Richard A. Yost ๐Ÿ“‚ Article ๐Ÿ“… 1997 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 225 KB ๐Ÿ‘ 2 views

## Electrospray ionization (ESI) tandem mass spectrometry collision-induced dissociation (CID) fragmentation processes of a series of nitroaromatic, nitramine and nitrate ester explosives were studied in the negative-ion mode using daughter-ion, parent-ion and neutral loss scans. 2,4,6-Trinitrotolu

Origin of mass shifts in the quadrupole
โœ James Patrick Murphy III; Richard A. Yost ๐Ÿ“‚ Article ๐Ÿ“… 2000 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 48 KB ๐Ÿ‘ 2 views

A novel hybrid tandem mass analyzer, coupling a quadrupole ion trap with a quadrupole mass filter, has been constructed to permit mass analysis of ions ejected from the ion trap. The initial application of this instrument is the investigation of the origin of mass shifts in the ion trap due to ion f

Investigation of the Mass Shifts Caused
โœ Wenjun Mo; John F. J. Todd ๐Ÿ“‚ Article ๐Ÿ“… 1996 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 479 KB ๐Ÿ‘ 2 views

An ion-coupling model has been proposed to predict and interpret the occurrence of mass shifts induced by the presence of ions of other m/z ratios in the ion trap mass spectrometer. The method of dynamically scanning the dipolar tickle frequency has been used to determine the mass shifts for two spe