𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Characterization and analysis of osteopontin-immobilized poly(2-hydroxyethyl methacrylate) surfaces

✍ Scribed by Martin, Stephanie M. ;Ganapathy, Ramesh ;Kim, Tae K. ;Leach-Scampavia, Deborah ;Giachelli, Cecilia M. ;Ratner, Buddy D.


Publisher
John Wiley and Sons
Year
2003
Tongue
English
Weight
257 KB
Volume
67A
Category
Article
ISSN
0021-9304

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

A wide array of technologies exist for the characterization and quantification of molecules present at surfaces. We have used several of these experimental and instrumental techniques for the analysis of a novel biomaterial surface. Osteopontin, an extracellular matrix molecule involved in wound‐healing processes, has been chosen as a relevant model protein to immobilize onto poly(2‐hydroxyethyl methacrylate) [poly(HEMA)]. Electron spectroscopy for chemical analysis and time‐of‐flight secondary ion mass spectrometry were used to verify the surface chemistry and the presence of protein. Iodination of osteopontin yielded quantitative data supportive of dose‐dependent immobilization. Enzyme‐linked immunosorbent assay was also used to investigate the presence of osteopontin on poly(HEMA). Finally, the cell adhesive properties of immobilized osteopontin were confirmed by using a bovine aortic endothelial cell adhesion assay. The use of multiple tools to characterize the many facets of a biomaterial surface will undoubtedly improve our understanding of the surface and facilitate the amelioration of in vivo performance. © 2003 Wiley Periodicals, Inc. J Biomed Mater Res 67A: 334–343, 2003


📜 SIMILAR VOLUMES


Physical characterization of microporous
✍ Migliaresi, C. ;Nicodemo, L. ;Nicolais, L. ;Passerini, P. 📂 Article 📅 1981 🏛 John Wiley and Sons 🌐 English ⚖ 479 KB

## Abstract Poly(2‐hydroxyethyl methacrylate)‐(PHEMA) has been prepared by polymerizing in presence of different types of water‐soluble additives, at various amounts, which were removed by swelling in water. Mechanical properties of swollen samples have been measured and analyzed by using the class

Intraocular biocompatibility of hydroxye
✍ Smetana, K. ;Šulc, J. ;Krčová, Z. ;Pitrová, Š. 📂 Article 📅 1987 🏛 John Wiley and Sons 🌐 English ⚖ 455 KB

A strip of partially hydrolyzed poly (2-hydroxyethyl methacrylate) containing 65%-75% H 2 0 was implanted intv the antenor eye chamber of 11 Chinchilla rabbits. No pathological changes were found in the iris or in the ciliary body. The pathological findings in the cornea accompanying implantation of

Ultrasonic characterization of water sor
✍ A. Maffezzoli; A.M. Luprano; G. Montagna; L. Nicolais 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 182 KB 👁 2 views

A complex mechanism characterizes the water uptake kinetics in hydrogels, as a consequence of the strong structural changes occurring in the material during the sorption process. The water sorption involves the transformation of a glassy, moderately crosslinked polymer in a rubbery material. In this

Wettability of hydrogels I. Poly(2-hydro
✍ Holly, Frank J. ;Refojo, Miguel F. 📂 Article 📅 1975 🏛 John Wiley and Sons 🌐 English ⚖ 483 KB

## Abstract The wettability characteristics of the contact lens material, PHEMA, with respect to water have been determined by using the sessile drop, and the captive air bubble techniques of contact angle goniometry. It is concluded that on PHEMA gels water does not spread spontaneously. Large hys