𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Capillary Electrophoresis of Nucleotides on Ucon-Coated Fused Silica Columns

✍ Scribed by K. Oneill; X.W. Shao; Z.X. Zhao; A. Malik; M.L. Lee


Publisher
Elsevier Science
Year
1994
Tongue
English
Weight
352 KB
Volume
222
Category
Article
ISSN
0003-2697

No coin nor oath required. For personal study only.

✦ Synopsis


Ucon-coated columns have been used to isolate nucleotides, such as ribonucleotides, deoxyribonucleotides, and pyridine nucleotides, by capillary zone electrophoresis. This neutral, hydrophilic column coating (Ucon) significantly reduced macromolecule adsorption and electroosmotic flow, which provides the maximum resolution of the nucleotides separated under moderate buffer conditions ( (\mathrm{pH}) about 5-6). The relative standard deviations of the nucleotides were less than (1 %). Low minimum detectable concentrations (about 2-8 (\mu \mathrm{M}) ) and quantities (about 70-360 fmol) of the ribonucleotides were obtained. A qualitative and quantitative analysis of the ribonucleotides in hybridoma cell extracts shows the applicability of the developed methodology for the determination of intracellular nucleotide pools under the desirable buffer conditions. 1994 Academic Press, Inc.


πŸ“œ SIMILAR VOLUMES


Polymethacryloxypropylhydrosiloxane deac
✍ A. FridstrΓΆm; N. Lundell; L. Nyholm; K.E. Markides πŸ“‚ Article πŸ“… 1997 πŸ› John Wiley and Sons 🌐 English βš– 128 KB πŸ‘ 2 views

A new polymer, polymethacryloxypropylhydrosiloxane PMAHS , has been developed and used as both a deactivating layer and an intermediate layer for stable coating of an uncharged polymer on fused silica capillaries in capillary electrophoresis. The deactivation procedure is based on a siliconhydride d

On the stability of micro-LC columns (pa
✍ De Weerdt, M. ;Dewaele, C. ;Verzele, M. πŸ“‚ Article πŸ“… 1987 πŸ› John Wiley and Sons 🌐 English βš– 316 KB

The life expectancy and resistance to flow, pressure shocks, solvent gradients, and bending of packed fused silica capillary columns (Micro-LC) are discussed. ## 2 Instrumentation Chromatographic measurements were carried out on a Varian 5020 (Varian Associates, Walnut Creek, CA, USA) and on a Per

Rapid analysis of charge variants of mon
✍ Yan He; Colleen Isele; Weiying Hou; Margaret Ruesch πŸ“‚ Article πŸ“… 2011 πŸ› John Wiley and Sons 🌐 English βš– 191 KB πŸ‘ 1 views

## Abstract A capillary zone electrophoresis (CZE) method was developed for the rapid analysis of charge heterogeneity of immunoglobulin G (IgG) monoclonal antibodies (mAbs). The separation was carried out in a short, dynamically coated fused‐silica capillary. A number of separation parameters were

A new method forin situ crosslinking of
✍ Liu, Huwei ;Zhang, Aiqing ;Jin, Yonghao ;Fu, Ruonong πŸ“‚ Article πŸ“… 1989 πŸ› John Wiley and Sons 🌐 English βš– 223 KB πŸ‘ 1 views

A new mixed crosslinking agent composed of dicumyl peroxide and tetra(methylvinyl)cyclotetrasiloxane was used to prepare fused silica capillary columns with in situ crosslinked stationary phases including PEG-SOM, SE-54, and OV-1. These columns proved to have good thermostability and inertness. As e