𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Capillary and packed column SFC/MS

✍ Scribed by Berry, A. J. ;Games, D. E. ;Mylchreest, I. C. ;Perkins, J. R. ;Pleasance, S.


Publisher
John Wiley and Sons
Year
1988
Tongue
English
Weight
394 KB
Volume
11
Category
Article
ISSN
0935-6304

No coin nor oath required. For personal study only.

✦ Synopsis


A frit restrictor interface for capillary column supercritical fluid chromatography/mass spectrometry (SFC/MS) has been constructed and used for the analysis of high boiling point alkanes. Packed column SFC/MS is described using both a moving belt liquid chromatographic/mass spectrometric interface and a thermospray source in the filament-on mode.


πŸ“œ SIMILAR VOLUMES


The application of capillary SFC, packed
✍ MacKay, Graham A. ;Reed, Graham D. πŸ“‚ Article πŸ“… 1991 πŸ› John Wiley and Sons 🌐 English βš– 465 KB

## Abstract Multi–component mixtures of controlled drugs, drug impurities, and adulterants have been analyzed by capillary SFC‐FID, packed column SFC‐UV, and capillary SFC‐MS. Isocratic packed column SFC has been performed with binary and ternary mobile phases using a single syringe pump. The combi

Packing material activity in packed capi
✍ De Weerdt, M. ;Dewaele, C. ;Verzele, M. ;Sandra, P. πŸ“‚ Article πŸ“… 1990 πŸ› John Wiley and Sons 🌐 English βš– 438 KB

## Abstract Several commercially available and home‐made reversed phase packing materials packed in capillary columns are evaluated for SFC with pure CO~2~ as mobile phase. Anilines and polycyclic aromatic hydrocarbons are used as test mixture. Some β€œon column endcapping” experiments are evaluated.

Preparation and evaluation of supercriti
✍ Daixin Tong; Keith D. Bartle; Anthony A. Clifford πŸ“‚ Article πŸ“… 1994 πŸ› John Wiley and Sons 🌐 English βš– 537 KB

## Abstract Preparation of packed capillary columns with supercritical carbon dioxide as the packing carrier is demonstrated; column performance was evaluated by both HPLC and SFC. It is shown that this procedure yields excellent column performance. The density of the packed bed can be controlled b

In-situ deactivation of packed columns f
✍ Zhang, Shigang ;Schindler, Brigitte ;Nicholson, Graham ;Bayer, Ernst πŸ“‚ Article πŸ“… 1995 πŸ› John Wiley and Sons 🌐 English βš– 237 KB

## Abstract Residual adsorptive activity of reversed phase (RP) column packings used in supercritical fluid chromatography (SFC) can be significantly reduced by a dynamic __in‐situ__ silanization with diphenyltetramethyldisilazane (DPTMDS). RP‐materials thus deactivated were characterized both chro

Column technology for packed capillary c
✍ Yukio Hirata πŸ“‚ Article πŸ“… 1990 πŸ› John Wiley and Sons 🌐 English βš– 679 KB

## Abstract The packed capillary column is one type of microcolumn. It is used increasingly in liquid chromatography, supercritical fluid chromatography, and multidimensional chromatography. In order to attain high efficiency with packed capillary columns, reliable column preparation methods must b