𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Biosensor for the determination of l-lysine

✍ Scribed by E. Vrbová; M. Marek; E. Ralys


Publisher
Elsevier Science
Year
1992
Tongue
English
Weight
384 KB
Volume
270
Category
Article
ISSN
0003-2670

No coin nor oath required. For personal study only.

✦ Synopsis


A biosensor for the determination of L-lysine was prepared, consisting of a Clark-type oxygen sensor and a convenient support with an immobilized enzyme system fixed to its surface. L-Lysine-a-oxidase was co-immobilized with catalase via the Ugi reaction using glutaraldehyde and cyclohexyl isocyanide either on a partially hydrolysed nylon net or on the preactivated or native collagen membrane. The consumption of oxygen was detected by the oxygen sensor. Hydrogen peroxide was decomposed by catalase to increase the sample throughout. The enzyme electrode prepared was tested from the viewpoint of its substrate specificity, pH and temperature effect on the enzyme activity and characterized by the specific and relative activity of the immobilized enzyme system. The linear range of biosensor response to the substrate was 6.7 × 10-6-6.7 x 10 -4 M; the apparent Michaelis constant (1.3 mM) and the stability of biosensor were also determined. The enzyme electrode was used for the determination of L-lysine in wheat extracts.


📜 SIMILAR VOLUMES


Benzoquinone-Mediated Biosensor for Ampe
✍ A. Surya N Murthy; Jyotsna Sharma 📂 Article 📅 1999 🏛 John Wiley and Sons 🌐 English ⚖ 145 KB 👁 2 views

An amperometric enzyme sensor for the analysis of D-lysine is described. The sensor uses benzoquinone as mediator for electron transfer between immobilized D-amino acid oxidase and a glassy carbon electrode. A linear current response, proportional to D-lysine concentration in the range 1±10 mM, was

Mitochondria-Based Amperometric Biosenso
✍ S. T. Girousi; A. A. Pantazaki; A. N. Voulgaropoulos 📂 Article 📅 2001 🏛 John Wiley and Sons 🌐 English ⚖ 68 KB 👁 2 views

A mitochondria based amperometric biosensor was developed for the determination of L-glutamic acid. The biosensor was characterized using hexacyanoferrate(III) as the electrochemical mediator. The electrochemical behavior of the redox couple hexacyanoferrate(II)a(III) was improved by incorporating o

Biosensor technology for determination o
✍ Yoko Nomura; Gab-Joo Chee; Isao Karube 📂 Article 📅 1998 🏛 John Wiley and Sons ⚖ 108 KB 👁 1 views

## Biochemical oxygen demand (BOD) is an important index for monitoring organic pollutants in water. The conventional standard method (5-day BOD test, BOD 5 ), however, is a complicated and time-consuming procedure, including a 5-day incubation, and also requires considerable experience and skill

Enzyme biosensor for determination of or
✍ Ashok Mulchandani; Priti Mulchandani; Wilfred Chen 📂 Article 📅 1998 🏛 John Wiley and Sons ⚖ 84 KB 👁 1 views

A potentiometric enzyme biosensor for the direct measurement of organophosphate pesticides was developed. The basic element of this enzyme biosensor was a pH electrode modified with an immobilized organophosphorus hydrolase layer formed by cross-linking OPH with bovine serum albumin and glutaraldehy