## Abstract A strong cation‐exchange (SCX) monolithic stationary phase was prepared in 75 μm id capillaries by direct __in situ__ polymerization of sulfopropyl methacrylate and polyethylene glycol diacrylate in a ternary porogen system consisting of methanol, cyclohexanol, and water. The resulting
Biocompatible polymeric monoliths for protein and peptide separations
✍ Scribed by Yun Li; Milton L. Lee
- Publisher
- John Wiley and Sons
- Year
- 2009
- Tongue
- English
- Weight
- 488 KB
- Volume
- 32
- Category
- Article
- ISSN
- 1615-9306
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
The concept of biocompatibility with reference to chromatographic stationary phases for separation of biomolecules (including proteins and peptides) is introduced. Biocompatible is a characteristic that indicates resistance to nonspecific adsorption of biomolecules and preservation of their structures and biochemical functions. Two types of biocompatible polymeric monoliths [i. e., polyacrylamide‐ and poly(meth)acrylate‐based monoliths] used for protein and peptide separations are reviewed in detail, with emphasis on size exclusion, ion exchange, and hydrophobic interaction chromatographic modes. Biocompatible monoliths for enzyme reactors are also included. The two main synthetic approaches to produce biocompatible monoliths are summarized, i. e., surface modification of a monolith that is not inherently biocompatible and direct copolymerization of hydrophilic monomers to form a biocompatible monolith directly. Integration of polyethylene glycol into the poly(meth)acrylate monolith network is becoming popular for reduction of non‐specific protein interactions.
📜 SIMILAR VOLUMES
## Protein and peptide separations on high surface area capillaries A 50 mm capillary that has been etched with ammonium hydrogen difluoride is evaluated as a separation medium for capillary electrochromatography. For a tryptic digest of transferrin, the etched capillary gave better resolution (mo
A range of high-performance liquid chromatography (HPLC) columns with internal diameters of 0.25 to 1.8 mm have been constructed by securing glass or plastic tubing into standard HPLC fittings. These were packed with chromatographic materials chosen for operation at moderate pressures with high flow
## Abstract Polymer‐based monoliths with zwitterionic surface character were synthesized in capillary columns following a two‐step approach to provide versatile electrochromatographic stationary phases exhibiting potentiality of both hydrophilic interaction and RP separation modes. UV‐initiated fre