Automated sample preparation using membrane microtiter extraction for bioanalytical mass spectrometry
โ Scribed by John Janiszewski; Richard P. Schneider; Keith Hoffmaster; Monica Swyden; David Wells; Hassan Fouda
- Publisher
- John Wiley and Sons
- Year
- 1997
- Tongue
- English
- Weight
- 163 KB
- Volume
- 11
- Category
- Article
- ISSN
- 0951-4198
No coin nor oath required. For personal study only.
โฆ Synopsis
The development and application of membrane solid phase extraction (SPE) in 96-well microtiter plate format is described for the automated analysis of drugs in biological fluids. The small bed volume of the membrane allows elution of the analyte in a very small solvent volume, permitting direct HPLC injection and negating the need for the time consuming solvent evaporation step. A programmable liquid handling station (Quadra 96) was modified to automate all SPE steps. To avoid drying of the SPE bed and to enhance the analytical precision a novel protocol for performing the condition, load and wash steps in rapid succession was utilized. A block of 96 samples can now be extracted in 10 min., about 30 times faster than manual solvent extraction or single cartridge SPE methods. This processing speed complements the high-throughput speed of contemporary high performance liquid chromatography mass spectrometry (HPLC/MS) analysis. The quantitative analysis of a test analyte (Ziprasidone) in plasma demonstrates the utility and throughput of membrane SPE in combination with HPLC/MS. The results obtained with the current automated procedure compare favorably with those obtained using solvent and traditional solid phase extraction methods. The method has been used for the analysis of numerous drug prototypes in biological fluids to support drug discovery efforts.
๐ SIMILAR VOLUMES
The 96 well solid phase extraction (SPE) operated by robot in the LC/MS/MS bioanalysis offered rapid sample preparation for drugs and metabolites in biological matrices, based on simultaneous extraction of 96 samples. The use of a disk as sorbent in the 96 well plate further improved the performance
A sensitive, specific, accurate and reproducible analytical method was developed and validated for the quantitation of the anticancer agent paclitaxel in human plasma. This procedure is based on high performance liquid chromatography/ion spray -tandem mass spectrometry. This methodology is highly sp
This work presents a simple method for obtaining homogeneous sample surfaces in matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOFMS) for the automated analysis of peptides and proteins. The sample preparation method is based on applying the sample/matrix mixture
A procedure that permits rapid development of an optimized solid phase extraction (SPE) method for the analysis of drugs in plasma by on-line solid phase extraction-mass spectrometry (SPE-MS) has been developed. This procedure employs the concept of manipulating the pH and the percentage of organic
Molecular ion yields and spectrum quality in plasma desorption mass spectrometry of peptides and proteins have been studied as a function of the method of sample preparation. Parameters like matrix preparation, pH of the sample solution, method of applying the sample on the matrix and sample quantit