Automated classification of short echo time in in vivo 1H brain tumor spectra: A multicenter study
✍ Scribed by A. Rosemary Tate; Carles Majós; Angel Moreno; Franklyn A. Howe; John R. Griffiths; Carles Arús
- Publisher
- John Wiley and Sons
- Year
- 2002
- Tongue
- English
- Weight
- 151 KB
- Volume
- 49
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Automated pattern recognition techniques are needed to help radiologists categorize MRS data of brain tumors according to histological type and grade. A major question is whether a computer program “trained” on spectra from one hospital will be able to classify those from another, particularly if the acquisition protocol is different. A subset of 144 histopathologically validated brain tumor spectra in the INTERPRET database, obtained from three of the collaborating centers, was grouped into meningiomas, low‐grade astrocytomas, and “aggressive tumors” (glioblastomas and metastases). Spectra from two centers formed the training set (94 spectra) while the third acted as the test set (50 spectra). Linear discriminant analysis successfully classified 48/50 in the test set; the remaining two were atypical cases. When the training and test sets were combined, 133 of the 144 spectra were correctly classified using the leave‐one‐out procedure. These spectra had been obtained using different sequences (STEAM and PRESS), different echo times (20, 30, 31, and 32 ms), different repetition times (1600 and 2000 ms), and different manufacturers' instruments (GE and Philips). Pattern recognition algorithms are less sensitive to acquisition parameters than had been expected. Magn Reson Med 49:29–36, 2003. © 2003 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
Short echo time in vivo STEAM 1 H MR spectra (4.7 T, TE=16 ms) of normal rat brain were fitted in the time domain using a VARPRO-like algorithm called AMARES which allows an inclusion of a large amount of prior knowledge. The prior knowledge was derived from phantom spectra of pure metabolite soluti
## Abstract Both ultrashort echo‐time STEAM and MEGA‐PRESS‐edited spectroscopy were used to validate noninvasive quantification of vitamin C (ascorbate) in the developing rat brain, where changes in ascorbate concentration have been reported. Despite strong overlap with resonances from glutamine, g
Localized in vivo 1 H NMR spectroscopy was performed with 2-ms echo time in the rat brain at 9.4 T. Frequency domain analysis with LCModel showed that the in vivo spectra can be explained by 18 metabolite model solution spectra and a highly structured background, which was attributed to resonances w
## Abstract Glycine is an amino acid present in mammalian brain, where it acts as an inhibitory and excitatory neurotransmitter. The two detectable protons of glycine give rise to a singlet at 3.55 ppm that overlaps with the more intense __myo__‐inositol resonances, and its measurement has traditio
## Abstract ## Purpose: To assess the reproducibility of ^1^H‐MR spectroscopic imaging (MRSI) of the human brain at 3T with volume selection by a double spin echo sequence for localization with adiabatic refocusing pulses (semi‐LASER). ## Materials and Methods: Twenty volunteers in two different