✦ Synopsis


Eight alditols were separated in ca. 80 mm as their borate complexes by stepwise elution with three borate buffers on a column packed with Hitachi 2633 resin. The alditols in the eluate were derivatized automatically to colored, fluorescent products by applying sequential reactions of periodate oxidation and Hantzsch condensation, and the products were detected either photometrically or fluorimetrically. This automated method allowed simultaneous determination of 20-500 and 20-200 nmol amounts of alditols by photometric and fluorimetric monitorings, respectively. The lower limits of detection were ca. 2 and 0.5 nmol, respectively. The interference by aldoses was slight. Aldoses may be also determined as alditols by direct injection of aqueous solutions to which excess amounts of sodium borohydride have been added. This method was applied with success to urinary alditol assay and to molecular weight determination by end group analysis.


πŸ“œ SIMILAR VOLUMES


Automated analysis of uronic acids by hi
✍ Susumu Honda; Shigeo Suzuki; Masaye Takahashi; Kazuaki Kakehi; Shigetake Ganno πŸ“‚ Article πŸ“… 1983 πŸ› Elsevier Science 🌐 English βš– 522 KB

A convenient method for the rapid and sensitive automated analysis of uronic acids, based on high-performance anion-exchange chromatography on a Hitachi 2633 column and photometric as well as fluorimetric postcolumn labeling with 2-cyanoacetamide, has been developed. This method allows the simultane

Rapid, automated analysis of monosacchar
✍ Susumu Honda; Masaye Takahashi; Kazuaki Kakehi; Shigetake Ganno πŸ“‚ Article πŸ“… 1981 πŸ› Elsevier Science 🌐 English βš– 637 KB

Biochemically important monosaccharides were rapidly separated by automated chromatography of their borate complexes on columns packed with newly developed anion-exchange resins, and sensitively detected by fluorimetric postlabeling with 2-cyanoacetamide. Optimization studies for stepwise, gradient,

Analysis of Glutathione and Glutathione
✍ Kevin J. Lenton; HΓ©lΓ¨ne Therriault; J.Richard Wagner πŸ“‚ Article πŸ“… 1999 πŸ› Elsevier Science 🌐 English βš– 73 KB

A method is described for the detection of glutathione (GSH) and glutathione disulfide (GSSG) based on a HPLC postcolumn reaction with ortho-phthalaldehyde (OPT) at pH 12 followed by fluorescence detection. Although similar methods have been reported, the high pH of the postcolumn reaction adds cons