Analysis and generalized correction of the effect of spatial gradient field distortions in diffusion-weighted imaging
✍ Scribed by R. Bammer; M. Markl; A. Barnett; B. Acar; M.T. Alley; N.J. Pelc; G.H. Glover; M.E. Moseley
- Publisher
- John Wiley and Sons
- Year
- 2003
- Tongue
- English
- Weight
- 1012 KB
- Volume
- 50
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Nonuniformities of magnetic field gradients can cause serious artifacts in diffusion imaging. While it is well known that nonlinearities of the imaging gradients lead to image warping, those imperfections can also cause spatially dependent errors in the direction and magnitude of the diffusion encoding. This study shows that the potential errors in diffusion imaging are considerable. Further, we show that retrospective corrections can be applied to reduce these errors. A general mathematical framework was formulated to characterize the contribution of gradient nonuniformities to diffusion experiments. The gradient field was approximated using spherical harmonic expansion, and this approximation was employed (after geometric distortions were eliminated) to predict and correct the errors in diffusion encoding. Before the corrections were made, the experiments clearly revealed marked deviations of the calculated diffusivity for fields of view (FOVs) generally used in diffusion experiments. These deviations were most significant farther away from the magnet's isocenter. For an FOV of 25 cm, the resultant errors in absolute diffusivity ranged from approximately –10% to +20%. Within the same FOV, the diffusion‐encoding direction and the orientation of the calculated eigenvectors can be significantly altered if the perturbations by the gradient nonuniformities are not considered. With the proposed correction scheme, most of the errors introduced by gradient nonuniformities can be removed. Magn Reson Med 50:560–569, 2003. © 2003 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract For diffusion‐weighted magnetic resonance imaging and under circumstances where patient movement can be modeled as rigid body motion, it is shown both theoretically and experimentally that translations and rotations produce phase errors which are zero‐ and first‐order, respectively, in
## Abstract ## Purpose To correct eddy‐current artifacts in diffusion tensor (DT) images without the need to obtain auxiliary scans for the sole purpose of correction. ## Materials and Methods DT images are susceptible to distortions caused by eddy currents induced by large diffusion gradients.
## Abstract In echo‐planar‐based diffusion‐weighted imaging (DWI) and diffusion tensor imaging (DTI), the evaluation of diffusion parameters such as apparent diffusion coefficients and anisotropy indices is affected by image distortions that arise from residual eddy currents produced by the diffusi
## Abstract ## Purpose To derive and implement a method for correcting spatial distortion caused by in vivo inhomogeneous static magnetic fields in echo‐planar imaging (EPI). ## Materials and Methods The reversed gradient method, which was initially devised to correct distortion in images genera
Gradient pulses used in most localization techniques induce time-dependent shifts in Bo that strongly distort NMR signals. A postprocessing correction method requiring no additional hardware is proposed. The phase shift produced by the Bo shift is calculated from a reference free induction decay (FI