𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Analysis and characterization of sophorolipids by liquid chromatography with atmospheric pressure chemical ionization

✍ Scribed by A. Nuñez; R. Ashby; T. A. Foglia; D. K. Y. Solaiman


Publisher
Springer
Year
2001
Tongue
English
Weight
503 KB
Volume
53
Category
Article
ISSN
0009-5893

No coin nor oath required. For personal study only.


📜 SIMILAR VOLUMES


Characterization of prenylated xanthones
✍ da Costa, Cristina T.; Dalluge, Joseph J.; Welch, Michael J.; Coxon, Bruce; Marg 📂 Article 📅 2000 🏛 John Wiley and Sons 🌐 English ⚖ 137 KB 👁 2 views

## Reversed -phase liquid chromatography with atmospheric pressure chemical ionization mass spectrometry (LC/APCI-MS) in the positive-ion mode was utilized to analyze crude ether extracts from the root bark of Maclura pomifera, a tree known to have a high content of prenylated xanthones and flavano

Liquid Chromatography/Mass Spectrometry
✍ Keiji Gamoh; Hiroyuki Abe; Katsuya Shimada; Suguru Takatsuto 📂 Article 📅 1996 🏛 John Wiley and Sons 🌐 English ⚖ 408 KB 👁 2 views

Liquid chromatography/mass spectrometry (LC/MS) with atmospheric pressure chemical ionization has been successfully applied to the simultaneous analysis of free brassinosteroids (polyhydroxylated steroids that serve as plant growth regulators) as their naphthaleneboronates. Of a range of analytical

Atmospheric pressure chemical ionization
✍ P. Manini; R. Andreoli; M. Careri; L. Elviri; M. Musci 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 241 KB 👁 2 views

An atmospheric pressure chemical ionization liquid chromatography/mass spectrometry (APCI-LC/MS) system was evaluated for the analysis of cholesterol oxidation products (COPs). High performance liquid chromatography separation of these compounds was performed under reversed-phase chromatographic con

Analysis of insect triacylglycerols usin
✍ Edita Kofroňová; Josef Cvačka; Pavel Jiroš; David Sýkora; Irena Valterová 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 355 KB 👁 1 views

## Abstract An HPLC non‐aqueous reversed‐phase separation system was adapted for analyzing insect triacylglycerols (TAG). The method uses two conventional Nova‐Pak C18 columns connected in series, for a total length of 45 cm. The mobile phase gradient is mixed from acetonitrile and 2‐propanol, and

The Analysis of β-Blockers by Capillary
✍ Kathryn A. Hutton; David E. Games 📂 Article 📅 1997 🏛 John Wiley and Sons 🌐 English ⚖ 285 KB 👁 2 views

Capillary liquid chromatography/mass spectrometry (LC/MS) is usually performed using electrospray ionization. Atmospheric pressure chemical ionization (APCI) has not been used since the flow rates involved (1-10 µL/min) are too low to effect ionization with a standard APCI source. Using a 320 µm ؋ 1