An inductively coupled plasma-time-of-flight mass spectrometer for elemental analysis. Part I: Optimization and characteristics

โœ Scribed by D.P. Myers; G. Li; P. Yang; G.M. Hieftje


Publisher
Elsevier Science
Year
1994
Tongue
English
Weight
886 KB
Volume
5
Category
Article
ISSN
1044-0305

No coin nor oath required. For personal study only.

โœฆ Synopsis


An inductively coupled plasma-time-of-flight mass spectrometer (ICP-TOFMS) has been constructed and evaluated for elemental analysis. The instrument produces analog spectra similar to those from quadrupole inductively coupled plasma mass spectrometers. The large abundance of Ar ions is deflected away from the microchannel plate detector to reduce detector dead time and space-charge complications. The ICP-TOFMS, operated in a linear (nonreflecting) mode, currently has a resolving power of 500 (full width at half maximum). Present ion optics employed in the instrument require a trade-off between signal-to-noise ratio and resolving power. In addition, mass-dependent kinetic energies in the supersonic beam created in the ICP mass spectrometer interface cause a mass bias in the right-angle TOFMS because the ions must be steered to the detector to compensate for their velocity in the supersonic beam direction. In the current design the sampling duty cycle is only approximately 3%, thereby limiting sensitivity. However, positive potentials applied to the right-angle extraction region can increase sensitivity by a factor of 2-4 by slowing down the ions that enter the extraction zone. The transmission efficiency of the TOFMS is approximately 20% and is limited by divergence of the ion packet in the drift tube.


๐Ÿ“œ SIMILAR VOLUMES


Preliminary Design Considerations and Ch
โœ D.P. Myers; G.M. Hieftje ๐Ÿ“‚ Article ๐Ÿ“… 1993 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 861 KB

Multielement analysis by means of plasma source mass spectrometry has evolved over the past decade primarily through the use of the quadrupole mass analyzer. In the present research a time-of-flight mass spectrometer (TOFMS) has been designed, built, and tested with an inductively coupled plasma (IC

Isotope ratios and abundance sensitivity
โœ D.P. Myers; P.P. Mahoney; G. Li; G.M. Hieftje ๐Ÿ“‚ Article ๐Ÿ“… 1995 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 877 KB

Isotope ratios and abundance sensitivities have been determined with an inductively coupled plasma-time-of-flight mass spectrometer (ICP-TOFMS). Abundance sensitivities are at least in the 10(6) range for low abundance ions that precede high abundance ions. Three methods of detection for isotope-rat

Simplex optimization of the plasma param
โœ Michael J. Ford; Les Ebdon; Robert C. Hutton; Steve J. Hill ๐Ÿ“‚ Article ๐Ÿ“… 1994 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 777 KB

A simplex procedure has been successfully applied to the optimization of both the plasma parameters and the ion optics of a commercial inductively coupled plasma mass spectrometry (ICP-MS) instrument for the maximization of SBRs for pneumatic nebulixation. The objective function for the simplex was