Preliminary Design Considerations and Characteristics of an Inductively Coupled Plasma-Time-of-Flight Mass Spectrometer
β Scribed by D.P. Myers; G.M. Hieftje
- Publisher
- Elsevier Science
- Year
- 1993
- Tongue
- English
- Weight
- 861 KB
- Volume
- 48
- Category
- Article
- ISSN
- 0026-265X
No coin nor oath required. For personal study only.
β¦ Synopsis
Multielement analysis by means of plasma source mass spectrometry has evolved over the past decade primarily through the use of the quadrupole mass analyzer. In the present research a time-of-flight mass spectrometer (TOFMS) has been designed, built, and tested with an inductively coupled plasma (ICP) supported with argon. The TOFMS offers higher speed, higher ion transmission, and measurement of all masses in one cycle of mass analysis. This paper outlines the considerations that were used to devise an appropriate geometry for the TOFMS, considering the known characteristics of the ICP ion source and the expected behavior of an ICP-MS interface. When linear and right-angle geometries are compared, the right-angle TOFMS seems far more appropriate as a mass analyzer in an ICP-MS instrument. The right-angle TOFMS was interfaced to an ICP and its preliminary characteristics have been evaluated. The mass spectrometer exhibits excellent speed and unit-mass resolution for the elements. However, the initial sensitivity is lower than originally estimated, probably because of poor ion transport from the ICP into the TOFMS. In addition, the ions produced from the plasma gas (argon) saturate the microchannelplate detector, prompting the implementation of a deflection scheme to remove much of the (\mathrm{Ar}^{+}). These initial observations as well as future endeavors are presented. O 1993 Academic Press. lnc.
π SIMILAR VOLUMES
The combination of a quadrupole orthogonal time-of-flight (Q-TOF) mass spectrometer with fast chromatography has been studied. It was found that the combination was capable of giving good accuracy of mass measurement for mass spectra with errors generally better than 5 ppm. In addition it was shown
An algorithm is suggested that allows the implementation of first order velocity (energy) focusing in a linear, single field, time-of-flight mass spectrometer (TOF/MS) over a broad mass range using a time-dependent mass-corrected extraction field. The interpolation formula for extraction field depen
## Abstract CE was coupled to inductively coupled plasma MS (ICPβMS) and ESIβMS to identify and quantify the arsenic species arsenobetaine (AsB), arsenite (As^III^), arsenate (As^V^), and dimethylarsinic acid (DMA). A GCβflame ionization detector (FID)βbased German standard method and ICPβMS were u
Total arsenic concentrations and the concentrations of individual arsenic compounds were determined in liver samples of pinnipeds [nine ringed seals (Phoca hispida), one bearded seal (Erginathus barbatus)] and cetaceans [two pilot whales (Globicephalus melas), one beluga whale (Deliphinapterus leucu