Preliminary Design Considerations and Characteristics of an Inductively Coupled Plasma-Time-of-Flight Mass Spectrometer

✍ Scribed by D.P. Myers; G.M. Hieftje


Publisher
Elsevier Science
Year
1993
Tongue
English
Weight
861 KB
Volume
48
Category
Article
ISSN
0026-265X

No coin nor oath required. For personal study only.

✦ Synopsis


Multielement analysis by means of plasma source mass spectrometry has evolved over the past decade primarily through the use of the quadrupole mass analyzer. In the present research a time-of-flight mass spectrometer (TOFMS) has been designed, built, and tested with an inductively coupled plasma (ICP) supported with argon. The TOFMS offers higher speed, higher ion transmission, and measurement of all masses in one cycle of mass analysis. This paper outlines the considerations that were used to devise an appropriate geometry for the TOFMS, considering the known characteristics of the ICP ion source and the expected behavior of an ICP-MS interface. When linear and right-angle geometries are compared, the right-angle TOFMS seems far more appropriate as a mass analyzer in an ICP-MS instrument. The right-angle TOFMS was interfaced to an ICP and its preliminary characteristics have been evaluated. The mass spectrometer exhibits excellent speed and unit-mass resolution for the elements. However, the initial sensitivity is lower than originally estimated, probably because of poor ion transport from the ICP into the TOFMS. In addition, the ions produced from the plasma gas (argon) saturate the microchannelplate detector, prompting the implementation of a deflection scheme to remove much of the (\mathrm{Ar}^{+}). These initial observations as well as future endeavors are presented. O 1993 Academic Press. lnc.


πŸ“œ SIMILAR VOLUMES


A preliminary study using fast gradient
✍ Michael J. Lee; Soraya MontΓ©; James Sanderson; Neville J. Haskins πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons 🌐 English βš– 94 KB πŸ‘ 2 views

The combination of a quadrupole orthogonal time-of-flight (Q-TOF) mass spectrometer with fast chromatography has been studied. It was found that the combination was capable of giving good accuracy of mass measurement for mass spectra with errors generally better than 5 ppm. In addition it was shown

An Approach to the Design of Mass-correl
✍ S. V. Kovtoun πŸ“‚ Article πŸ“… 1997 πŸ› John Wiley and Sons 🌐 English βš– 111 KB πŸ‘ 3 views

An algorithm is suggested that allows the implementation of first order velocity (energy) focusing in a linear, single field, time-of-flight mass spectrometer (TOF/MS) over a broad mass range using a time-dependent mass-corrected extraction field. The interpolation formula for extraction field depen

Capillary electrophoresis with inductive
✍ BjΓΆrn Meermann; Marc Bartel; Andy Scheffer; Stefan TrΓΌmpler; Uwe Karst πŸ“‚ Article πŸ“… 2008 πŸ› John Wiley and Sons 🌐 English βš– 356 KB πŸ‘ 1 views

## Abstract CE was coupled to inductively coupled plasma MS (ICP‐MS) and ESI‐MS to identify and quantify the arsenic species arsenobetaine (AsB), arsenite (As^III^), arsenate (As^V^), and dimethylarsinic acid (DMA). A GC‐flame ionization detector (FID)‐based German standard method and ICP‐MS were u

Determination of arsenic compounds in ma
✍ W. Goessler; A. Rudorfer; E. A. Mackey; P. R. Becker; K. J. Irgolic πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 158 KB πŸ‘ 2 views

Total arsenic concentrations and the concentrations of individual arsenic compounds were determined in liver samples of pinnipeds [nine ringed seals (Phoca hispida), one bearded seal (Erginathus barbatus)] and cetaceans [two pilot whales (Globicephalus melas), one beluga whale (Deliphinapterus leucu