✦ Synopsis


Affinity protection chromatography for efficient labeling of antibodies for use in affinity capillary electrophoresis

Capillary electrophoresis immunoassay (CEIA) is shown to be substantially more sensitive to the antibody (Ab) reagent quality than are immunosorbent methods such as enzyme-linked immunosorbent assays (ELISA). Cyanine 5 (Cy5)-labeled monoclonal anti-ovalbumin (mAb*) was inactive for CEIA of ovalbumin (Ov), yet was functional in ELISA for Ov. ELISA showed the mAb* was at least ten times less active, accounting for the poor CEIA performance. Labeled polyclonal Ab was inactive for a dye to protein ratio greater than 1.6. An affinity protection chromatography procedure (APC) was developed for Ab labeling, which avoided degradation of the Ab binding site. Ov was covalently bound to cyanogen bromide activated cellulose gel in a column, and used to capture the Ab. The coupling efficiency for Ov to the gel was 74-97%, Ab could then be bound with 95-100% efficiency, and Ab* was recovered in 50% yield following labeling on the column. This procedure was performed successfully in three different laboratories, indicating the robustness of the optimized APC synthetic method. No inactive Ab* could be detected in the APC product. The CEIA detection limit for ovalbumin using APC labeled mAb was 173 nM, when [Ab*] was fixed at 163 nM. The association constants of mAb and mAb* were determined by CEIA.


πŸ“œ SIMILAR VOLUMES


Use of weak monoclonal antibodies for af
✍ Maria BergstrΓΆm; Arne Lundblad; Peter PΓ₯hlsson; Sten Ohlson πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 60 KB πŸ‘ 2 views

When using weakly interacting ligands in affinity chromatography, it is possible to take advantage of a true chromatographic process in the separation, as compared with traditional affinity chromatography which is rather an on/off process. In this work, weak monoclonal antibodies were immobilized on

Use of Capillary Affinity Electrophoresi
✍ R. Kuhn; R. Frei; M. Christen πŸ“‚ Article πŸ“… 1994 πŸ› Elsevier Science 🌐 English βš– 362 KB

Capillary affinity electrophoresis was used to study the interactions of lectins from Tetragonolobus purpureas with L-(-)-fucose 1-phosphate. The electrophoretic mobilities of three lectin peaks were influenced by the complexation with the negatively charged fucose derivative. A model that allows th