✦ Synopsis


A new method of liquid sample introduction for a time-of-flight mass spectrometer (TOF-MS) has been developed by applying the method of matrix-assisted laser desorption ionization to aerosols. Analyte biomolecules are dissolved in a methanol solvent along with a UVabsorbing matrix and formed into an aerosol with a pneumatic nebulizer. The aerosol particles are dried in a heated skimmer tube before ionization by pulsed 355-nm UV laser radiation. Mass analysis is achieved in a linear TOF-MS. Results for the ionization of bovine insulin (5733.5 Mw) are reported.


πŸ“œ SIMILAR VOLUMES


Aerosol Matrix-assisted Laser Desorption
✍ Russell, David H.; Beeson, Michelle D. πŸ“‚ Article πŸ“… 1996 πŸ› John Wiley and Sons 🌐 English βš– 837 KB

The effects of methanol, ethanol, propan-2-01 and acetonitrile on the aerosol matrix-assisted laser desorptionlionization (MALDI) ion signal of hradykinin, bovine insulin and myoglobin were examined. The effect of these solvents mixed with water was also studied. The aerosol MALDI ion signal for eac

Application of matrix-assisted laser des
✍ M. A. Stowers; A. L. van Wuijckhuijse; J. C. M. Marijnissen; B. Scarlett; B. L. πŸ“‚ Article πŸ“… 2000 πŸ› John Wiley and Sons 🌐 English βš– 65 KB πŸ‘ 2 views

Matrix-assisted laser desorption/ionization (MALDI) mass spectra were obtained from single biological aerosol particles using an aerosol time-of-flight mass spectrometer (ATOFMS). The inlet to the ATOFMS was coupled with an evaporation/condensation flow cell that allowed the aerosol to be coated wit

Chemical reactivity in matrix-assisted l
✍ C. Enjalbal; B. Sauvagnat; F. Lamaty; R. Lazaro; J. Martinez; P. Mouchet; F. Rou πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons 🌐 English βš– 139 KB πŸ‘ 2 views

During the control of a multistep organic synthesis on a soluble polymer (PEG) by matrix-assisted laser desorption/ionization (MALDI) mass spectrometry, a chemical reactivity was encountered when the matrix was acidic, for the samples where the amino moiety of the anchored compounds was protected as

Matrix-assisted Laser Desorption/Ionizat
✍ Silvia Catinella; Pietro Traldi; Costante Pinelli; Evaristo Dallaturca; Renzo Ma πŸ“‚ Article πŸ“… 1996 πŸ› John Wiley and Sons 🌐 English βš– 798 KB

The protein content of several cow milks was investigated by matrix-assisted laser desorptionhonization (MALDI) mass spectrometry. In particular, milk from four dinerent breeds of cow (Holstein Frisons, Brown Swiss, Jersey and Reggiana) at the same lactation stage and under the same feeding system w

Quantitative bioanalysis using matrix-as
✍ S. Jespersen; W. M. A. Niessen; U. R. Tjaden; J van der Greef πŸ“‚ Article πŸ“… 1995 πŸ› John Wiley and Sons 🌐 English βš– 612 KB

## Abstract The application of matrix‐assisted laser desorption/ionization mass spectrometry (MALDI‐MS) for quantitative analysis was investigated with the use of internal standards. Three peptides/proteins in the mass range 1000–12000 were tested and the effect of various internal standards was ev