Polyclonal antihuman CY -thrombin antibodies produced in rabbits reacted minimally (<0.05%) in solution with human prothrombin. However, when prothrombin was adsorbed to artificial surfaces such as polyvinyl chloride (PVC), the crossreactivity of surface-bound prothrombin with antibody IgG to thromb
Adsorption and reactivity of human prothrombin to artificial surfaces
β Scribed by Chuang, Hanson Y. K. ;Mitra, Sankar P.
- Publisher
- John Wiley and Sons
- Year
- 1984
- Tongue
- English
- Weight
- 773 KB
- Volume
- 18
- Category
- Article
- ISSN
- 0021-9304
No coin nor oath required. For personal study only.
β¦ Synopsis
Abstract
Human prothrombin in Tyrode's solution, in mock plasma (albumin, fibrinogen, and IgG mixture), and in citrated plasma adsorbs to Cuprophane, polyvinylchloride, and polyacrylonitrile surfaces. The adsorption of prothrombin is maximal in Tyrode's solution and minimal in plasma. The surface concentrations of prothrombin are highest on polyacrylonitrile, second on polyvinylchloride, and lowest on Cuprophane at all prothrombin concentrations tested in the bulk solution. Qualitative tests show that prothrombin adsorbed to polyvinylchloride can be activated by Taipan snake venom to generate thrombin that clots fibrinogen. However, more quantitative tests indicate that only part of the adsorbed prothrombin on all three materials can be activated to form thrombin exhibiting amidolytic activity. The partial reactivity of adsorbed prothrombin is further confirmed by release of ^125^Iβpeptide from surface bound ^125^Iβprothrombin after treatment with Australian Taipan snake venom. Prothrombin bound to Cuprophane seems to promote granulocyte adhesion, but has no effect on platelet adhesion.
π SIMILAR VOLUMES
## Abstract Thrombin adsorbed onto Cuprophane or poly(vinyl chloride) (PVC) was shown to be inactive with respect to amidase activity. Desorbed thrombin from these two artificial surfaces showed only low amidase activity. However, in the presence of albumin, the surfaceβbound thrombin appeared to e
The objective of this work is to develop bloodcontacting surfaces that will dissolve nascent clots that may begin to form on them. Surfaces were prepared consisting of a polyurethane to which a coating reagent was attached covalently by photochemical methods. The coating reagent was a polyacrylamide
The adsorption of human serum albumin and human fibrinogen on flat surfaces was quantitatively determined by measuring the decrease in UV absorption in the adsorption solution. The applicability of the methacrylate), and cellophane. method is discussed for hydrophilic and hydrophobic materials. The