The adsorption of fibrinogen and plasminogen from plasma to silica glass, sulfonated silica glass, and lysinederivatized silica glass has been investigated. The data indicate that the sulfonated material has a high affinity for both fibrinogen and plasminogen, but that the ratio of plasminogen to fi
Adsorption of plasminogen from human plasma to lysine-containing surfaces
✍ Scribed by McClung, W. G. ;Clapper, D. L. ;Hu, S.-P. ;Brash, J. L.
- Publisher
- John Wiley and Sons
- Year
- 2000
- Tongue
- English
- Weight
- 373 KB
- Volume
- 49
- Category
- Article
- ISSN
- 0021-9304
No coin nor oath required. For personal study only.
✦ Synopsis
The objective of this work is to develop bloodcontacting surfaces that will dissolve nascent clots that may begin to form on them. Surfaces were prepared consisting of a polyurethane to which a coating reagent was attached covalently by photochemical methods. The coating reagent was a polyacrylamide with lysine and benzophenone (for photochemical attachment) moieties pendant to the chains. It was hypothesized that via the lysine moieties such surfaces would show specific binding affinity for plasminogen, the principal component of the fibrinolytic system in blood. Surfaces of varying lysine content in which the lysine was bound through the ␣-amino groups, leaving the ⑀-amino groups free, were investigated. A control surface in which the lysine was bound through the ⑀-amino groups was also examined. Advancing water contact angles showed the surfaces to be hydrophilic. Hydrophilicity was found to decrease as the lysine content increased. Adsorption of plasminogen from plasma was studied using radioiodinated plasminogen as a tracer. For the ⑀-lysine surfaces, adsorption increased with increasing lysine content and reached a value of 1.2 g/cm 2 for the surface with the highest lysine content, that is, in the range expected for a compact monolayer of plasminogen. The control surfaces, which contained either no lysine or lysine in which the ⑀-amino groups were unavailable, adsorbed very small amounts of plasminogen. Immunoblots were obtained for the proteins eluted from the surfaces after incubation with plasma. For the control surfaces, most of the proteins tested for (some 20 in all) were present. However, for the surface containing the highest concentration of ⑀-lysine, only plasminogen was detected in a significant amount. It is concluded that the ⑀-lysine surface adsorbs plasminogen to the exclusion of the other plasma proteins. Studies to examine the fibrinolytic properties of these surfaces will constitute the next phase of this work.
📜 SIMILAR VOLUMES
## Abstract Three polyethylene oxide‐polyurethane‐polyethylene oxide (PEO‐PU‐PEO) block copolymers of variable PEO block size (MW 550, 2000, and 5000) were used to modify the surface of a conventional segmented polyurethane (PU) with the objective of inhibiting interactions with proteins. The surfa