𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Adaptive correction technique for 3D reconstruction of fluorescence microscopy images

✍ Scribed by Y.Q. Guan; Y.Y. Cai; X. Zhang; Y.T. Lee; M. Opas


Publisher
John Wiley and Sons
Year
2008
Tongue
English
Weight
521 KB
Volume
71
Category
Article
ISSN
1059-910X

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Recent advances in high‐resolution imaging have provided valuable novel insights into structural relationships within cells and tissues both in vitro and in vivo. An analysis of this kind is regularly done by optical sectioning using either confocal or deconvolution microscopy. However, the reconstruction of 3D images suffers from light scattering and absorption with increasing depth by finite transparency of the used media. Photobleaching of fluorochromes has been especially troublesome and often the only remedy for loss of signal during optical sectioning is to reduce the number of sections. This causes disparities in the xy and z dimensions of voxels, which lead to vertical distortion of the original stack of images and necessitates interpolation. Interpolation is necessary to fill up the gaps between consecutive sections in the original image stack to obtain cubic voxels. The present manuscript describes a novel method for adaptive compensation of attenuation of light intensity in stacks of fluorescence microscopy images that is based on a physical model of light attenuation. First, we use a fast interpolation technique to generate a cubic voxel‐based volume stack with the aid of a contribution look up table. With the contribution look up table, multiple calculations are avoided, which substantially reduces the computational time without compromising the accuracy of the restoration procedure. Second, each section within the resulting volume is processed to rectify its intensity values that have been altered due to photobleaching and scattering and absorption. The method allows to define the last good section in the stack and the correction is then done automatically. Microsc. Res. Tech., 2008. © 2007 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


High-resolution solid modeling of biolog
✍ Michael C. Ferko; Brian W. Patterson; Peter J. Butler 📂 Article 📅 2006 🏛 John Wiley and Sons 🌐 English ⚖ 488 KB

Optical-sectioning, digital fluorescence microscopy provides images representing temporally- and spatially-resolved molecular-scale details of the substructures of living cells. To render such images into solid models for further computational analyses, we have developed an integrated system of imag

Adaptive-weighted cubic B-spline using l
✍ C. Indhumathi; Y.Y. Cai; Y.Q. Guan; M. Opas; J. Zheng 📂 Article 📅 2012 🏛 John Wiley and Sons 🌐 English ⚖ 315 KB

## Abstract Confocal laser scanning microscopy has become a most powerful tool to visualize and analyze the dynamic behavior of cellular molecules. Photobleaching of fluorochromes is a major problem with confocal image acquisition that will lead to intensity attenuation. Photobleaching effect can b

Spectral phase-corrected GRAPPA reconstr
✍ Xiaoping Zhu; Andreas Ebel; Jim X. Ji; Norbert Schuff 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 727 KB

## Abstract MR spectroscopic (MRS) images from a large volume of brain can be obtained using a 3D echo‐planar spectroscopic imaging (3D‐EPSI) sequence. However, routine applications of 3D‐EPSI are still limited by a long scan time. In this communication, a new approach termed “spectral phase‐correc

Surface imaging microscopy using an ultr
✍ Dane A. Gerneke; Gregory B. Sands; Ramanujan Ganesalingam; Purva Joshi; Bryan J. 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 531 KB

## Abstract Three‐dimensional reconstruction of large tissue volumes using histological thin sections poses difficulties because of registration of sections, section distortion, and the possibility of incomplete data set collection due to section loss. We have constructed an integrated surface imag