𝔖 Bobbio Scriptorium
✦   LIBER   ✦

High-resolution solid modeling of biological samples imaged with 3D fluorescence microscopy

✍ Scribed by Michael C. Ferko; Brian W. Patterson; Peter J. Butler


Publisher
John Wiley and Sons
Year
2006
Tongue
English
Weight
488 KB
Volume
69
Category
Article
ISSN
1059-910X

No coin nor oath required. For personal study only.

✦ Synopsis


Optical-sectioning, digital fluorescence microscopy provides images representing temporally- and spatially-resolved molecular-scale details of the substructures of living cells. To render such images into solid models for further computational analyses, we have developed an integrated system of image acquisition, processing, and rendering, which includes a new empirical technique to correct for axial distortions inherent in fluorescence microscopy due to refractive index mismatches between microscope objective immersion medium, coverslip glass, and water. This system takes advantage of the capabilities of ultra-high numerical aperture objectives (e.g. total internal reflection fluorescence microscopy) and enables faithful three-dimensional rendering of living cells into solid models amenable to further computational analysis. An example of solid modeling of bovine aortic endothelial cells and their nuclei is presented. Since many cellular level events are temporally and spatially confined, such integrated image acquisition, processing, rendering, and computational analysis, will enable, in silico, the generation of new computational models for cell mechanics and signaling.


πŸ“œ SIMILAR VOLUMES


Effect of fixatives on calf thymocytes c
✍ G. Mascetti; L. Vergani; A. Diaspro; S. Carrara; G. Radicchi; C. Nicolini πŸ“‚ Article πŸ“… 1996 πŸ› John Wiley and Sons 🌐 English βš– 913 KB

Two common fixatives-glutaraldehyde and eth-anoYacetic acid mixture-were studied to understand their effects on DNA distribution inside the cell nucleus. Native calf thymocytes were analyzed by using a DNA selective fluorescent dye (DAPI) and computational optical sectioning microscopy on isolated c

High resolution 3D imaging of the inner
✍ James N. Lee; Brian D. King; Dennis L. Parker; Henry R. Buswell; H. Ric Harnsber πŸ“‚ Article πŸ“… 1996 πŸ› John Wiley and Sons 🌐 English βš– 375 KB

A fast spin-echo pulse requence is described that producer high resolution images of the Inner ear Without suoceptibility artifacts. It uses thin overlapping slices that can be reformatted in multiple projections to provide a view of the 3D geometry of Inner ear structures, such aa the cochlea, vest

High temporal resolution breathheld 3D F
✍ Dan W. Rettmann; Manojkumar Saranathan; Katherine C. Wu; Clerio F. Azevedo; Davi πŸ“‚ Article πŸ“… 2007 πŸ› John Wiley and Sons 🌐 English βš– 460 KB

## Abstract ## Purpose To develop a gated single‐breathhold, high temporal resolution three‐dimensional (3D) CINE imaging technique and to evaluate its accuracy in volumetric and functional quantification in patients with chronic myocardial infarction. ## Materials and Methods A 3D CINE steady‐s