๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Accurate determination of sulfur at trace levels by isotope dilution mass spectrometry

โœ Scribed by Kazuo Watanabe


Publisher
Elsevier Science
Year
1983
Tongue
English
Weight
354 KB
Volume
147
Category
Article
ISSN
0003-2670

No coin nor oath required. For personal study only.

โœฆ Synopsis


Sulfur is recovered as silver sulfide which is converted to sulfur dioxide by combustion with pure oxygen at low pressure in 1 min. Isotopic analysis of as little as 40 ccg of sulfur is possible with a precision better than 0.2%. The technique is applicable to materials such as Cu, Fe, Sn, Ti, Zr, zircaloys and standard rocks.


๐Ÿ“œ SIMILAR VOLUMES


Accurate analysis of trace pentachloroph
โœ FuHai Su; Pan Zhang ๐Ÿ“‚ Article ๐Ÿ“… 2011 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 134 KB

## Abstract A highly accurate method for measuring pentachlorophenol (PCP) concentrations in textile samples was developed. This highly accurate method for the analysis of textile samples is valuable, given the inherent challenges associated with the complexity of the sample matrix. This method can

Accurate and precise determination of ch
โœ J.G. van Raaphorst; H.M. Haremaker; P.A. Deurloo; B. Beemsterboer ๐Ÿ“‚ Article ๐Ÿ“… 1994 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 491 KB

A method for the determination of chromium with the help of thermal ionization isotope dilution mass spectrometty was developed. In this type of mass spectrometry a stable signal depends mainly on the purity of the loaded sample. Therefore, the main effort was the development of a method for the sep

Determination of deuterium level in biol
โœ Andrew D. Penman; Iain A. Wright ๐Ÿ“‚ Article ๐Ÿ“… 1987 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 313 KB ๐Ÿ‘ 2 views

Water is produced by vacuum sublimation of biological fluids directly into reaction vessels in preparation for reduction using zinc. Following heating to 450 "C the hydrogen produced is admitted directly to the mass spectrometer. The standard derivation, u,,, of analysis of water samples was 1.08-1.

Determination of cyclophosphamide and if
โœ Sannolo, N.; Miraglia, N.; Biglietto, M.; Acampora, A.; Malorni, A. ๐Ÿ“‚ Article ๐Ÿ“… 1999 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 83 KB ๐Ÿ‘ 2 views

A specific and sensitive method based on gas chromatography/tandem mass spectrometry with on-column injection was developed to quantify simultaneously cyclophosphamide and ifosphamide in urine by using trophosphamide as an internal standard. The urine samples were extracted with diethyl ether and de