An enzyme-linked immunosorbent assay (ELISA) which used 4-methylumbelliferyl phosphate as an enzyme substrate was used to quantify two plant cytokinins. This assay detected as little as 0.03 pmol (approximately 10 pg) of cytokinin in microplate wells coated with a cytokinin-ovalbumin conjugate. The method measured competition between free cytokinin and the bound conjugate for reaction with monoclonal anticytokinin antibodies and used a standard curve prepared by use of known amounts of free cytokinin to quantify hormone levels in unknown samples. Standard curves which consisted of logit/log plots of fluorescence units versus picomoles of competing cytokinin measured from 0.03 to 256 pmol (approximately 10-85000 picograms) of zeatin riboside (ZR) or isopentenyl adenosine. The fluorescence ELISA was compared with radioimmunoassay for the quantification of ZR in wheat (Triticum aestivum L., cultivar Stephens) seed samples. This fluorescence ELISA method is recommended for use in combination with a fractionation method, such as HPLC, to quantify cytokinins present in plant extracts. 0 1987 Academic Rest, Inc.


πŸ“œ SIMILAR VOLUMES


Assay of follitropin and lutropin by flu
✍ David A. Armbruster; F. Armbruster; Leah C. Hawes πŸ“‚ Article πŸ“… 1990 πŸ› John Wiley and Sons 🌐 English βš– 438 KB

Recently developed fluorescent enzyme imrnunoassays (FEls) for follitropin (FSH) and lutropin (LH) designed for the Stratus analyzer were compared with a typical dual FSH-LH radioimmunoassay (RIA) procedure. The FEls use monoclonal antibodies in a sandwich reaction scheme similar to that of immunor

A particle concentration fluorescence im
✍ Bruce A. Kottke; Nina D. Bren πŸ“‚ Article πŸ“… 1994 πŸ› Elsevier Science 🌐 English βš– 520 KB

The quantitation of Lp(a) by immunoassay presents a major technical problem, because the molecular mass of the (a) protein of Lp(a) can vary between 419 000 and 838 000 Da (Gaubatz et al. (1990) J. Lipid Res. 31,603-612), and this variability is determined by at least 24 alleles of the (a) gene. In

A robotic immunoassay system for deterge
✍ Larry S. Miller; Balwant S. Bhullar; Victor S. Moore; Laurie J. Scovell; Jill La πŸ“‚ Article πŸ“… 1994 πŸ› Elsevier Science 🌐 English βš– 846 KB
A convenient homogeneous enzyme immunoas
✍ May L. Chiu; Tina T.-C. Tseng; Harold G. Monbouquette πŸ“‚ Article πŸ“… 2011 πŸ› Portland Press 🌐 English βš– 302 KB

## Abstract A convenient homogeneous enzyme immunoassay for estradiol is described. Unlike heterogeneous immunoassays, which require time‐consuming separation steps or expensive automated systems, homogeneous immunoassays, wherein all reagents are freely suspended in bulk solution, can be simple an