𝔖 Bobbio Scriptorium
✦   LIBER   ✦

A novel approach for correlative light electron microscopy analysis

✍ Scribed by Giuseppe Vicidomini; Maria C. Gagliani; Katia Cortese; Jens Krieger; Peter Buescher; Paolo Bianchini; Patrizia Boccacci; Carlo Tacchetti; Alberto Diaspro


Publisher
John Wiley and Sons
Year
2009
Tongue
English
Weight
531 KB
Volume
73
Category
Article
ISSN
1059-910X

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Correlative light and electron microscopy (CLEM) is a multimodal technique of increasing utilization in functional, biochemical, and molecular biology. CLEM attempts to combine multidimensional information from the complementary fluorescence light microscopy (FLM) and electron microscopy (EM) techniques to bridge the various resolution gaps. Within this approach the very same cell/structure/event observed at level can be analyzed as well by FLM and EM. Unfortunately, these studies turned out to be extremely time consuming and are not suitable for statistical relevant data. Here, we describe a new CLEM method based on a robust specimen preparation protocol, optimized for cryosections (Tokuyasu method) and on an innovative image processing toolbox for a novel type of multimodal analysis. Main advantages obtained using the proposed CLEM method are: (1) hundred times more cells/structures/events that can be correlated in each single microscopy session; (2) three‐dimensional correlation between FLM and EM, obtained by means of ribbons of serial cryosections and electron tomography microscopy (ETM); (3) high rate of success for each CLEM experiment, obtained implementing protection of samples from physical damage and from loss of fluorescence; (4) compatibility with the classical immunogold and immunofluorescence labeling techniques. This method has been successfully validated for the correlative analysis of Russel Bodies subcellular compartments. Microsc. Res. Tech., 2010. Β© 2009 Wiley‐Liss, Inc.


πŸ“œ SIMILAR VOLUMES


High-pressure Freezing in CLEM : A Corre
✍ Paul Verkade πŸ“‚ Article πŸ“… 2007 πŸ› Wiley (John Wiley & Sons) βš– 351 KB πŸ‘ 1 views

Research methods using so-called Correlative Light Electron Microscopy (CLEM) techniques have gained increasing attention in recent years. Most techniques have focused on the light microscopy part of the process. The processing for electron microscopy, however, deserves attention as well to get the

Combined fluorescent and gold immunoprob
✍ Powell, Richard D.; Halsey, Carol M.R.; Hainfeld, James F. πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 526 KB

Immunoprobes which incorporate both a fluorescent label and a 1.4 nm gold cluster compound were prepared by covalent conjugation to FabЈ antibody fragments of the Nanogold cluster label followed by a fluorescent moiety. These new immunoconjugates allow the collection of two complementary sets of dat

Polyethylene glycol (PEG) embedding and
✍ Kondo, Hisatake ;Ushiki, Tatsuo πŸ“‚ Article πŸ“… 1985 πŸ› Wiley (John Wiley & Sons) 🌐 English βš– 592 KB

The polyethylene glycol (PEG) embedding and subsequent deembedding method was applied to the observation of general tissues in scanning electron microscopy (SEMI. Resulting SEM images were of high quality. It was demonstrated that intermicroscopic correlation of images between light microscopy 0, sc

Preparation of collagen gel matrices for
✍ Turner, J. W. ;Sandra, A. πŸ“‚ Article πŸ“… 1989 πŸ› Wiley (John Wiley & Sons) 🌐 English βš– 347 KB πŸ‘ 1 views

Cells grown on type I hydrated collagen gels require special techniques for sample preparation and processing in order to optimize the removal of all reagents from the collagen matrix and prevent artifactual shrinkage. This method includes cutting out a small block of the collagen gel, postfixation,