✦ Synopsis


Abstract

Based on the chemiluminescence (CL) intensity generated from the potassium ferricyanide [K~3~Fe(CN)~6~]–rhodamine 6G system in sodium hydroxide (NaOH) medium, a new sensitive flow‐injection chemiluminescence (FI–CL) method has been developed, validated and applied for the determination of three kinds of H~2~‐receptor antagonists: cimetidine (CIMT), ranitidine (RANT) hydrochloride and famotidine (FAMT). Under the optimum conditions, the linear range for the determination was 1.0 × 10^−9^–7.0 × 10^−5^ g/ml for CIMT, 1.0 × 10^−9^–5.0 × 10^−5^ g/mL for RANT hydrochloride and 5.0 × 10^−9^–7.0 × 10^−5^ g/mL for FAMT. During 11 repeated measurements of 1.0 × 10^−6^ g/mL sample solutions, the relative standard deviations (RSDs) were all <5%. The detection limit was 8.56 × 10^−10^ g/mL for CIMT, 8.69 × 10^−10^ g/mL for RANT hydrochloride and 2.35 × 10^−9^ g/mL for FAMT (S:N = 3). This method has been successfully implemented for the analysis of H~2~‐receptor antagonists in pharmaceuticals. Copyright © 2007 John Wiley & Sons, Ltd.


📜 SIMILAR VOLUMES


Development of a sensitive flow-injectio
✍ Seikh Mafiz Alam; Mohammad Mainul Karim; Sang Hak Lee; Saikh Mohammad Wabaidur; 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 353 KB 👁 2 views

## Abstract A simple chemiluminometric method using flow injection has been developed for the determination of laevodopa, based on its sensitizing effect on the weak chemiluminescence (CL) reaction between Na~2~SO~3~ and acidic KMnO~4~. Under optimum experimental conditions, the CL intensity was li

Flow-injection chemiluminescence method
✍ Nan-Nan Wang; Yan-Qing Shao; Yu-Hai Tang; He-Ping Yin; Xiao-Zhong Wu 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 235 KB 👁 1 views

## Abstract A sensitive and simple flow‐injection chemiluminescence (FI‐CL) method, which was based on the CL intensity generated from the redoxreaction of potassium permanganate (KMnO~4~)–formaldehyde in vitriol (H~2~SO~4~) medium, has been developed, validated and applied for the determination of

Flow-injection method for the determinat
✍ Amir Waseem; Mohammad Yaqoob; Abdul Nabi 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 151 KB 👁 1 views

## Abstract A two‐channel flow‐injection (FI) method is reported for the determination of iodide and iodine by its enhancement effect on the Ru(bpy)~3~^3+^–NADH chemiluminescence (CL) system. The limit of detection (3 s of blank) was 1.0 × 10^–9^ mol/L iodide/iodine, with a sample throughput of 60/