𝔖 Bobbio Scriptorium
✦   LIBER   ✦

A High-Performance Liquid Chromatographic Method for the Determination of 8-Oxo-7,8-dihydro-2′-deoxyguanosine in Urine from Man and Rat

✍ Scribed by Christoph Lengger; Gerhard Schöch; Heinrich Topp


Publisher
Elsevier Science
Year
2000
Tongue
English
Weight
142 KB
Volume
287
Category
Article
ISSN
0003-2697

No coin nor oath required. For personal study only.

✦ Synopsis


The renally excreted amount of 8-oxo-7,8-dihydro-2'-deoxyguanosine (oxo(8)dG) is a potential marker of oxidative DNA damage by reactive oxygen species. We have developed a high-performance liquid chromatographic (HPLC) method to determine oxo(8)dG in urine from humans and Wistar rats. First, 300 microl of filtered urine is prefractionated by solid phase extraction (BAKERBOND SPE C(18) Polar Plus column). Then, the HPLC separation of the fraction containing oxo(8)dG is performed using four HPLC columns (two cation exchange and two C(18) columns) in series with an automated column switching technique. Quantification of oxo(8)dG is performed by electrochemical detection (Coulochem II, ESA Inc.). Limit of detection was 0.4 nM oxo(8)dG. Recovery of oxo(8)dG added respectively in 11 or 8 concentration steps (range, 4-74 or 2-23 nM) to a pooled human or rat urine was 104.1 +/- 4.3 or 104.5 +/- 7.7%. Precision of sixfold analysis of a pooled human or rat urine carried out respectively on the same day was 2.2 or 2.4% relative standard deviation. Normal excretion rates of oxo(8)dG in healthy adult humans (five females, six males; body weight, 70.7 +/- 11 kg) and male Wistar rats (body weight, 309 +/- 13 g) were 281.7 +/- 179.1 and 333.2 +/- 47.4 pmol oxo(8)dG/day/kg weight, respectively.


📜 SIMILAR VOLUMES


Monitoring of 8-oxo-7,8-dihydro-2′-deoxy
✍ Masatoki Katayama; Yoshifumi Matsuda; Kensuke Kobayashi; Satoru Kaneko; Hiromich 📂 Article 📅 2006 🏛 John Wiley and Sons 🌐 English ⚖ 235 KB 👁 1 views

A new, simple and sensitive pre-column fluorescence derivatization high-performance liquid chromatographic method for the determination of the oxidative DNA stress marker, 8-oxo-7,8-dihydro-2′-deoxyguanosine, was developed. Solidphase extraction using an Oasis HLB cartridge avoided troublesome sampl

High-performance liquid chromatographic
✍ Hui Wang; Guan Ye; Yi-Hong Tang; Hai-Yan Zhu; Rong-Rong Ma; Zhao-Ling Sun; Cheng 📂 Article 📅 2006 🏛 John Wiley and Sons 🌐 English ⚖ 174 KB 👁 2 views

A reversed-phase high-performance liquid chromatography assay for mangiferin in rat plasma and urine was developed. Rutin was employed as an internal standard. The mobile phase consisted of acetonitrile-water (16:84, v/v) containing 3% acetic acid at a flow rate of 1 mL/min. Detection was at 257 and

A simple and cost effective method for t
✍ Brian Crow; Michael Bishop; Kasey Kovalcik; Dean Norton; Joe George; J. Alexande 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 281 KB 👁 2 views

## Abstract A rapid and high‐throughput method for the determination of urinary levels of the oxidative stress biomarker, 8‐hydroxy‐2′‐deoxyguanosine (8‐OH‐dG), has been developed and validated using liquid chromatography combined with electrospray ionization tandem mass spectrometry (LC‐MS/MS). Th

A high-performance liquid chromatographi
✍ Heinrich Topp; Gernot Sander; Gesa Heller-Schöch; Gerhard Schöch 📂 Article 📅 1985 🏛 Elsevier Science 🌐 English ⚖ 471 KB

A simple and reliable HPLC method for quantitative determination of pseudouridine and uric acid in human urine and serum using a cation-exchange resin is described. This method is straightfonvard (12 runs of urine samples per day since the sample is only diluted into buffer and then chromatographed)