𝔖 Bobbio Scriptorium
✦   LIBER   ✦

A flow-injection continuous filtration approach for the automatic determination of monoclonal antibodies

✍ Scribed by J.M. Fernández-Romero; M.D.Luque de Castro


Publisher
Elsevier Science
Year
1996
Tongue
English
Weight
661 KB
Volume
331
Category
Article
ISSN
0003-2670

No coin nor oath required. For personal study only.

✦ Synopsis


An unsegmented continuous manifold for development of a heterogeneous immunoassay has been developed in which a microfilter located prior to the detector retains the precipitate formed in the immunochemical reaction. The system used to check the performance of the dynamic approach is monoclonal mouse immunoglobulin G (IgG) as analyte and its corresponding antimouse immunoglobulin G labelled with peroxidase. The derivatizing reaction used to monitor the immunoreaction is based on the oxidation of 4-hydroxyphenylacetic acid with hydrogen peroxide in the presence of the peroxidase bound to the antimouse IgG, which was monitored fluorimetrically (A,,=3 15 nm and X,,=425 nm). The method for the determination of monoclonal mouse -1gG shows a linear range between 1 and 200 ng ml-' (3=0.9997, n=lO) with an RSD < 3% at 10 and 100 ng ml-' (n=33). The 3a detection limit is 0.1 ng ml-'. The approach should be generally applicable for the determination of monoclonal antibodies.


📜 SIMILAR VOLUMES


Comparison of different flow injection a
✍ J.M. Fernandez-Romero; M.D.Luque de Castro; M. Valcarcel 📂 Article 📅 1989 🏛 Elsevier Science 🌐 English ⚖ 496 KB

Three configurations based on the principles behind flow injection analysis (FIA) are proposed for the automatic determination of enzymatic activity. The proposed approaches are normal, stopped-flow and open-closed FIA. The comparative study of the methods developed from these approaches allows the

Continuous flow-injection-atomic absorpt
✍ L.Lahuerta Zamora; J.Martínez Calatayud 📂 Article 📅 1995 🏛 Elsevier Science 🌐 English ⚖ 544 KB

A flow-injection procedure for the indirect determination of the new drug Ondansetron is proposed. The method is based on the reaction of the drug in an oxidative solid-phase reactor included in the flow assembly. The reactor was made by lead dioxide physically entrapped by polymerization; the relea

Flow-injection immunoanalysis, a versati
✍ Zheng-Liang Zhi 📂 Article 📅 1999 🏛 John Wiley and Sons 🌐 English ⚖ 122 KB

Flow-injection immunoanalysis (FIIA) is a novel and automatic technique combining flowinjection approach with specific antibodies to complement the step of an immunoassay in a flowthrough column format. This short review focuses on new FIIA contributions for environmental analysis problems with spec

Automatic continuous-flow determination
✍ J.S. Cosano; M.D.Luque de Castro; M. Valcárcel 📂 Article 📅 1995 🏛 Elsevier Science 🌐 English ⚖ 472 KB

A spectrophotometric method for the determination of sulphite in the presence of up to 200-fold of thiosulphate is proposed. The derivatizing reaction, which is based on the decoloration of p-rosaniline in neutral or slightly basic medium, is developed in an unsegmented flow system. A linear calibra