𝔖 Bobbio Scriptorium
✦   LIBER   ✦

A Duplexed Microsphere-Based Fluorescent Immunoassay

✍ Scribed by Ferenc Szurdoki; Karri L. Michael; David R. Walt


Publisher
Elsevier Science
Year
2001
Tongue
English
Weight
191 KB
Volume
291
Category
Article
ISSN
0003-2697

No coin nor oath required. For personal study only.

✦ Synopsis


Microsphere-based immunoassays are described for the simultaneous measurement of the clinically important drugs digoxin and theophylline. Competitive immunoassays were performed using haptenized microspheres and antibodies labeled with horseradish peroxidase. Enzyme-catalyzed reporter deposition (CARD) resulted in immunofluorescence signal amplification. Two encoding dyes were used to differentiate analytical signals from microspheres containing assays for the two analytes. An epifluorescence microscope and a CCD camera interfaced with a computer were utilized to measure fluorescence signals of individual microspheres. The microspheres from a duplexed assay were mounted on microscope slides as well as inserted into wells etched into the distal ends of optical imaging fibers. Fluorescence images from both formats were captured. In the experiments using microscope slides, the immunoassays were successfully duplexed and only marginal interferences at high analyte concentrations were observed. Preliminary results suggest that simultaneous determination of the two analytes using a fiber-based sensor-array format is feasible, but requires further development before precise quantitative analyses are possible.


πŸ“œ SIMILAR VOLUMES


The use of CdTe quantum dot fluorescent
✍ Qiang Ma; Xinyan Wang; Yabing Li; Xingguang Su; Qinhan Jin πŸ“‚ Article πŸ“… 2007 πŸ› John Wiley and Sons 🌐 English βš– 264 KB πŸ‘ 2 views

## Abstract Polystyrene fluorescent microspheres prepared by deposition of CdTe quantum dots (QDs) are used in an immunoassay in this study. CdTe QDs/polyelectrolyte multilayers on the surface of polystyrene microspheres have been formed by layer‐by‐layer self‐assembly via electrostatic interaction

The sensitive detection and quantitation
✍ Thomas M. McHugh; Maurene K. Viele; Eric S. Chase; Diether J. Recktenwald πŸ“‚ Article πŸ“… 1997 πŸ› John Wiley and Sons 🌐 English βš– 86 KB πŸ‘ 2 views

Antibody to HCV core and NS3 was quantified by using a microsphere immunoassay and flow cytometry. Antibody to core and NS3 was elevated in the 85 seropositive blood donors tested. The amount of either antibody varied over two logs although greater variation was seen with the antibody to NS3 than wa