๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

98/03980 Low-NOx-emission system for boilers in Power Plant III


Book ID
104286430
Publisher
Elsevier Science
Year
1998
Weight
208 KB
Volume
39
Category
Article
ISSN
0140-6701

No coin nor oath required. For personal study only.

โœฆ Synopsis


An eight-week test programme was carried out on a test burner with 2.5 MW thermal output in the IFRF test furnace in Ijmuiden, The Netherlands. The burner test was accompanied by numerical calculations and cold flow experiments. This led to the application of the burner in a utility boiler with a thermal capacity of 32 MW per burner, recommissioned in summer 1995 after retrofitting the burners. Burner operation performance did not experience problems. Experimental data are reported and the possibilities of adapting the burner to existing units are addressed.


๐Ÿ“œ SIMILAR VOLUMES


98/00500 Low-NOx-emission system for boi
๐Ÿ“‚ Article ๐Ÿ“… 1998 ๐Ÿ› Elsevier Science โš– 199 KB

The paper describes the fuel compositions of coal-water pastes (CWP) for PFBC boilers or furnaces, which comprise a first solid combustible having a CSN (crucible swelling number) of 0 or 112, a second solid combustible having a CSN of > 1, and liquids. The solid combustibles include coal, coke, pet

98/02255 Operation of an OP-230 boiler e
๐Ÿ“‚ Article ๐Ÿ“… 1998 ๐Ÿ› Elsevier Science โš– 196 KB

09 Combustion (burners, combustion systems) experimental study was then carried out to verify the model. The 300 MW once-through boiler system is used as an example. The capacity for heat recovery in the de-aerator tank was shown, by both the theoretical and the experimental analyses, to be largely