𝔖 Bobbio Scriptorium
✦   LIBER   ✦

3 Tesla and 7 Tesla MRI of multiple sclerosis cortical lesions

✍ Scribed by Emma C. Tallantyre; Paul S. Morgan; Jennifer E. Dixon; Ali Al-Radaideh; Matthew J. Brookes; Peter G. Morris; Nikos Evangelou


Publisher
John Wiley and Sons
Year
2010
Tongue
English
Weight
459 KB
Volume
32
Category
Article
ISSN
1053-1807

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Cortical lesions are prevalent in multiple sclerosis but are poorly detected using MRI. The double inversion recovery (DIR) sequence is increasingly used to explore the clinical relevance of cortical demyelination. Here we evaluate the agreement between imaging sequences at 3 Tesla (T) and 7T for the presence and appearance of individual multiple sclerosis cortical lesions. Eleven patients with demyelinating disease and eight healthy volunteers underwent MR imaging at 3T (fluid attenuated inversion recovery [FLAIR], DIR, and T~1~‐weighted magnetization prepared rapid acquisition gradient echo [MP‐RAGE] sequences) and 7T (T~1~‐weighted MP‐RAGE). There was good agreement between images for the presence of mixed cortical lesions (involving both gray and white matter). However, agreement between imaging sequences was less good for purely intracortical lesions. Even after retrospective analysis, 25% of cortical lesions could only be visualized on a single MRI sequence. Several DIR hyperintensities thought to represent cortical lesions were found to correspond to signal arising from extracortical blood vessels. High‐resolution 7T imaging appeared useful for confidently classifying the location of lesions in relation to the cortical/subcortical boundary. We conclude that DIR, FLAIR, and MP‐RAGE imaging sequences appear to provide complementary information during the detection of multiple sclerosis cortical lesions. High resolution 7T imaging may facilitate anatomical localization of lesions in relation to the cortical boundary. J. Magn. Reson. Imaging 2010;32:971–977. © 2010 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


In vivo multiple-mouse MRI at 7 Tesla
✍ Nicholas A. Bock; Brian J. Nieman; Johnathan B. Bishop; R. Mark Henkelman 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 245 KB

## Abstract We developed a live high‐field multiple‐mouse magnetic resonance imaging method to increase the throughput of imaging studies involving large numbers of mice. Phantom experiments were performed in 7 shielded radiofrequency (RF) coils for concurrent imaging on a 7 Tesla MRI scanner outfi

Detecting lesions in multiple sclerosis
✍ Amir Eissa; R. Marc Lebel; Jeff R. Korzan; Anna E. Zavodni; Kenneth G. Warren; I 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 348 KB

## Abstract ## Purpose To demonstrate 4.7 Tesla (T) imaging methods for visualizing lesions in multiple sclerosis in the human brain using phase susceptibility‐weighting and T2 weighting. ## Materials and Methods Seven patients with relapsing‐remitting multiple sclerosis were imaged at 4.7T usin

7 tesla MRI of microbleeds and white mat
✍ Jens M. Theysohn; Oliver Kraff; Stefan Maderwald; Markus Barth; Susanne C. Ladd; 📂 Article 📅 2011 🏛 John Wiley and Sons 🌐 English ⚖ 302 KB

## Abstract ## Purpose: To evaluate 7T MRI in the assessment of cerebrovascular alterations as seen in vascular dementia by means of detection of cerebral microbleeds (CMB) and depiction of white matter lesions (WML). 7T imaging was evaluated with respect to 1.5T. ## Materials and Methods: Ten h

Ultrashort echo time MRI of cortical bon
✍ Roland Krug; Peder Eric Zufall Larson; Chunsheng Wang; Andrew J. Burghardt; Doug 📂 Article 📅 2011 🏛 John Wiley and Sons 🌐 English ⚖ 196 KB

## Abstract ## Purpose: To implement and examine the feasibility of a three‐dimensional (3D) ultrashort TE (UTE) sequence on a 7 Tesla (T) clinical MR scanner in comparison with 3T MRI at high isotropic resolution. ## Materials and Methods: Using an in‐house built saddle coil at both field stren

Sodium MRI of the human kidney at 3 Tesl
✍ Nimrod Maril; Yael Rosen; Glenn H. Reynolds; Alex Ivanishev; Long Ngo; Robert E. 📂 Article 📅 2006 🏛 John Wiley and Sons 🌐 English ⚖ 337 KB

## Abstract The sodium concentration gradient in the kidney (from the cortex to the medulla) serves to regulate fluid homeostasis and is tightly coupled to renal function. It was previously shown that renal function and pathophysiology can be characterized in rat kidneys by measuring the sodium gra

Fast T2*-weighted MRI of the prostate at
✍ Rulon L. Hardman; Fadi El-Merhi; Adam J. Jung; Steve Ware; Ian M. Thompson; Harr 📂 Article 📅 2011 🏛 John Wiley and Sons 🌐 English ⚖ 314 KB 👁 1 views

## Abstract ## Purpose: To describe a rapid T2\*‐weighted (T2\*W), three‐dimensional (3D) echo planar imaging (EPI) sequence and its application in mapping local magnetic susceptibility variations in 3 Tesla (T) prostate MRI. To compare the sensitivity of T2\*W EPI with routinely used T1‐weighted