## Abstract Current implementations of coronary artery magnetic resonance angiography (MRA) suffer from limited coverage of the coronary arterial system. Whole‐heart coronary MRA was implemented based on a free‐breathing steady‐state free‐precession (SSFP) technique with magnetization preparation.
Whole heart magnetization-prepared steady-state free precession coronary vein MRI
✍ Scribed by Christian T. Stoeck; Yuchi Han; Dana C. Peters; Peng Hu; Susan B. Yeon; Kraig V. Kissinger; Beth Goddu; Lois Goepfert; Warren J. Manning; Sebastian Kozerke; Reza Nezafat
- Publisher
- John Wiley and Sons
- Year
- 2009
- Tongue
- English
- Weight
- 411 KB
- Volume
- 29
- Category
- Article
- ISSN
- 1053-1807
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Purpose
To compare two coronary vein imaging techniques using whole‐heart balanced steady‐state free precession (SSFP) and a targeted double‐oblique spoiled gradient‐echo (GRE) sequences in combination with magnetization transfer (MT) preparation sequence for tissue contrast improvement.
Materials and Methods
Nine healthy subjects were imaged with the proposed technique. The results are compared with optimized targeted MT prepared GRE acquisitions. Both quantitative and qualitative analyses were performed to evaluate each imaging method.
Results
Whole‐heart images were successfully acquired with no visible image artifact in the vicinity of the coronary veins. The anatomical features and visual grading of both techniques were comparable. However, the targeted small slab acquisition of the left ventricular lateral wall was superior to whole‐heart acquisition for visualization of relevant information for cardiac resynchronization therapy (CRT) lead implantation.
Conclusion
We demonstrated the feasibility of whole‐heart coronary vein MRI using a 3D MT‐SSFP imaging sequence. A targeted acquisition along the lateral left ventricular wall is preferred for visualization of branches commonly used in CRT lead implantation. J. Magn. Reson. Imaging 2009;29:1293–1299. © 2009 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract The purpose of this work was to investigate a new magnetization preparation scheme for navigator steady‐state free precession (SSFP) 3D coronary MR angiography (MRA) that executes the navigator and fat saturation pulses in steady state after the dummy RFs in order to minimize the delay
## Abstract ## Purpose To evaluate the feasibility of improving 3.0T steady‐state free precession (SSFP) whole‐heart coronary magnetic resonance angiography (MRA) using short‐TR (repetition time) VIPR (vastly undersampled isotropic projection reconstruction). ## Materials and Methods SSFP is hig
## Abstract Magnetization prepared segmented acquisition requires a view order that maximizes signal contrast during the acquisition of the central portion of __k__‐space. Steady state free precession (SSFP) acquisition further requires a view order that minimizes changes in phase‐encoding gradient
## Abstract Magnetization transfer imaging (MTI) by means of MRI exploits the mobility of water molecules in tissue and offers an alternative contrast mechanism beyond the more commonly used mechanisms based on relaxation times. A cardiac MTI method was implemented on a commercially available 1.5 T
## Abstract ## Purpose To demonstrate the feasibility of three‐dimensional thick‐partition, contrast‐enhanced, catheter‐directed coronary artery magnetic resonance angiography (MRA) and test the hypothesis that three‐dimensional imaging improves coronary artery background contrast‐to‐noise ratio (